2 Va. Admin. Code § 5-585-1700

Current through Register Vol. 41, No. 8, December 2, 2024
Section 2VAC5-585-1700 - Manual and mechanical warewashing equipment, chemical sanitization - temperature, pH, concentration, and hardness

A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subdivision 3 of 2VAC5-585-1900 shall meet the criteria specified under 2VAC5-585-3380, shall be used in accordance with the EPA-registered label use instructions,P and shall be used as follows:

1. A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart;P

Minimum Concentration

Minimum Temperature

mg/L (ppm)

pH 10 or less°F (°C)

pH 8.0 or less°F (°C)

25-49

120 (49)

120 (49)

50-99

100 (38)

75 (24)

100

55 (13)

55 (13)

2. An iodine solution shall have a:
a. Minimum temperature of 68°F (20°C);P
b. pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies the solution is effective;P and
c. Concentration between 12.5 mg/L (ppm) and 25 mg/L (ppm);P
3. A quaternary ammonium compound solution shall:
a. Have a minimum temperature of 75°F (24°C);P
b. Have a concentration as specified under 2VAC5-585-3380 and as indicated by the manufacturer's use directions included in the labeling;P and
c. Be used only in water with 500 mg/L (ppm) hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions;P
4. If another solution of a chemical specified under subdivisions 1 through 3 of this section is used, the operator shall demonstrate to the department that the solution achieves sanitization and the use of the solution shall be approved;P or
5. If a chemical sanitizer other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions;P and
6. If a chemical sanitizer is generated by a device located on site at the food establishment, it shall be used as specified in subdivisions 1 through 4 of this section and shall be produced by a device that:
a. Complies with regulation as specified in §§ 2(q)(1) and 12 of the Federal Insecticide, Fungicide, and Rodenticide Act (7 USC § 136(q)(1) and 7 USC § 136j);P
b. Complies with 40 CFR 152.500 and 40 CFR 156.10;P
c. Displays the EPA device manufacturing facility registration number on the device;Pf and
d. Is operated and maintained in accordance with manufacturer's instructions.Pf

2 Va. Admin. Code § 5-585-1700

Derived from Virginia Register Volume 24, Issue 2, eff. October 16, 2007; Amended, Virginia Register Volume 32, Issue 22, eff. 7/12/2016; Amended, Virginia Register Volume 37, Issue 19, eff. 6/24/2021.

Statutory Authority: § 3.2-5121 of the Code of Virginia.