Ga. Comp. R. & Regs. 120-3-27-.20

Current through Rules and Regulations filed through October 17, 2024
Rule 120-3-27-.20 - Electrical Equipment
(1) The National Electrical Code, NFPA 70 1984, latest adopted version is hereby adopted as a rule and all future amendments shall be accepted as adopted.
(2) This document may be purchased from the National Fire Protection Association, Battermarch Park, Quincy, MA 02269.
(3) All electrical wiring and equipment used for amusement rides or for lighting shall be installed and maintained in accordance with the Rule adopted in (1) above.
(4) The outlets of electrical power lines carrying more than 120 volts shall be clearly marked to show their voltage.
(5) All electrical transformer substations shall be properly enclosed and proper warning signs shall be posted.
(6) Electrical wiring and equipment located outdoors shall be of such quality and so constructed or protected that exposure to weather will not interfere with its normal operation.
(7) Elevated power lines crossing access or other roads within the grounds of a carnival or amusement park shall be so suspended as to provide a vertical clearance of at least twelve feet from the road surface or three feet above any vehicle used within the grounds of a carnival or amusement park. A horizontal clearance of at least three feet shall be provided on each side of the normal passage space of vehicles.

Ga. Comp. R. & Regs. R. 120-3-27-.20

O.C.G.A. Sec. 25-15-59.

Original Rule entitled "Electrical Equipment "adopted. F. Sep. 4, 2013; eff. Sept. 24, 2013.