Rule 120-3-27-.21 - Grounding
(1) No overcurrent protection device shall be installed in neutral or grounding conductors.
(2) Where electrical power is supplied for an amusement ride by a generating system, the generator and all equipment shall be properly grounded.
(3) All receptacles and attachment plugs shall be of the grounding type.
(4) Each electrically powered amusement ride shall be effectively grounded. The grounding shall be made effective as to all non-current carrying metal parts which may become energized and which are exposed to contact by any persons.
(5) Grounding which does not have a resistance to ground of 25 ohms or less shall be augmented by one additional electrode of any of the types specified in Section 250-53 of the Rule referenced in Rule 120-3-27-.21.

Ga. Comp. R. & Regs. R. 120-3-27-.21