Wis. Admin. Code NR § 256.33

Current through May 28, 2024
Section NR 256.33 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable
(1) Any plant, including noncontinuous direct dischargers, which casts primarily malleable iron where metal poured is equal to or less than 3,557 tons per year or casts primarily steel, shall achieve the copper, lead, zinc, and total phenols effluent limitations contained in s. NR 256.32. Grinding scrubber operations may not discharge process wastewater pollutants to waters of the state.
(2) Except as provided in 40 CFR 125.30 to 125.32, any plant, including noncontinuous direct dischargers, which casts primarily malleable iron where metal poured is greater than 3,557 tons per year or casts primarily ductile or gray iron shall achieve the following BAT effluent limitations. Grinding scrubber operations may not discharge process wastewater pollutants to waters of the state.

TABLE 47

FERROUS CASTING SUBCATEGORY

CASTING CLEANING OPERATIONS

BAT Effluent Limitations

Noncontinuous Direct Dischargers

Maximum for any 1 day

Maximum for monthly average

Maximum for any 1 day

Maximum for monthly average

Annual average

Pollutant or pollutant property

kg/1,000 kkg (pounds per million pounds) of metal poured

mg/l(1)

mg/l(1)

(2)

Copper (T)

0.0129

0.0071

0.29

0.16

0.0029

Lead (T)

0.0237

0.0116

0.53

0.26

0.0067

Zinc (T)

0.0437

0.0165

0.98

0.37

0.0116

(1) These concentrations shall be multiplied by the ratio of (5.33/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.

(2) kg/1,000 kkg (pounds per million pounds) of metal poured.

TABLE 48

FERROUS CASTING SUBCATEGORY

CASTING QUENCH OPERATIONS

BAT Effluent Limitations

Noncontinuous Direct Dischargers

Maximum for any 1 day

Maximum for monthly average

Maximum for any 1 day

Maximum for monthly average

Annual average

Pollutant or pollutant property

kg/1,000 kkg (pounds per million pounds) of metal poured

mg/l(1)

mg/l(1)

(2)

Copper (T)

0.0138

0.0076

0.29

0.16

0.0031

Lead (T)

0.0252

0.0124

0.53

0.26

0.0071

Zinc (T)

0.0466

0.0176

0.98

0.37

0.0124

(1) These concentrations shall be multiplied by the ratio of (5.7/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.

(2) kg/1,000 kkg (pounds per million pounds) of metal poured.

TABLE 49

FERROUS CASTING SUBCATEGORY

DUST COLLECTION SCRUBBER OPERATIONS

BAT Effluent Limitations

Noncontinuous Direct Dischargers

Maximum for any 1 day

Maximum for monthly average

Maximum for any 1 day

Maximum for monthly average

Annual average

Pollutant or pollutant property

kg/62.3 million Sm3 (pounds per billion SCF) of air scrubbed

mg/l(1)

mg/l(1)

(2)

Copper (T)

0.218

0.12

0.29

0.16

0.0488

Lead (T)

0.398

0.195

0.53

0.26

0.113

Zinc (T)

0.736

0.278

0.98

0.37

0.195

Total phenols

0.646

0.225

0.86

0.3

0.15

(1) These concentrations shall be multiplied by the ratio of (0.09/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 SCF of air scrubbed) for a specific plant.

(2) kg/62.3 million Sm3 (pounds per billion SCF) of air scrubbed.

TABLE 50

FERROUS CASTING SUBCATEGORY

INVESTMENT CASTING

BAT Effluent Limitations

Noncontinuous Direct Dischargers

Maximum for any 1 day

Maximum for monthly average

Maximum for any 1 day

Maximum for monthly average

Annual average

Pollutant or pollutant property

kg/1,000 kkg (pounds per million pounds) of metal poured

mg/l(1)

mg/l(1)

(2)

Copper (T)

3.19

1.76

0.29

0.16

0.716

Lead (T)

5.84

2.86

0.53

0.26

1.65

Zinc (T)

10.8

4.07

0.98

0.37

2.86

(1) These concentrations shall be multiplied by the ratio of (1,320/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.

(2) kg/1,000 kkg (pounds per million pounds) of metal poured.

TABLE 51

FERROUS CASTING SUBCATEGORY

MELTING FURNACE SCRUBBER OPERATIONS (1)

BAT Effluent Limitations

Noncontinuous Direct Dischargers

Maximum for any 1 day

Maximum for monthly average

Maximum for any 1 day

Maximum for monthly average

Annual average

Pollutant or pollutant property

kg/62.3 million Sm3 (pounds per billion SCF) of air scrubbed

mg/l(1)

mg/l(1)

(2)

Copper (T)

1.02

0.561

0.29

0.16

0.228

Lead (T)

1.86

0.911

0.53

0.26

0.526

Zinc (T)

3.44

1.3

0.98

0.37

0.911

Total phenols

3.01

1.05

0.86

0.3

0.701

(1) In a multiple ferrous melting furnace scrubber configuration, each discrete wet scrubbing device with an associated wastewater discharge shall be given the mass allowance specified. The allowance will be identical for each device and based on the airflow of the exhaust gas stream that passes through the multiple scrubber configuration.

(2) These concentrations shall be multiplied by the ratio of (0.42/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 SCF of air scrubbed) for a specific plant.

(3) kg/62.3 million Sm 3 (pounds per billion SCF) of air scrubbed

TABLE 52

FERROUS CASTING SUBCATEGORY

MOLD COOLING OPERATIONS

BAT Effluent Limitations

Noncontinuous Direct Dischargers

Maximum for any 1 day

Maximum for monthly average

Maximum for any 1 day

Maximum for monthly average

Annual average

Pollutant or pollutant property

kg/1,000 kkg (pounds per million pounds) of metal poured

mg/l(1)

mg/l(1)

(2)

Copper (T)

0.0428

0.0236

0.29

0.16

0.0096

Lead (T)

0.0783

0.0384

0.53

0.26

0.0222

Zinc (T)

0.0145

0.0546

0.98

0.37

0.0384

(1) These concentrations shall be multiplied by the ratio of (17.7/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.

(2) kg/1,000 kkg (pounds per million pounds) of metal poured.

TABLE 53

FERROUS CASTING SUBCATEGORY

SLAG QUENCH OPERATIONS

BAT Effluent Limitations

Noncontinuous Direct Dischargers

Maximum for any 1 day

Maximum for monthly average

Maximum for any 1 day

Maximum for monthly average

Annual average

Pollutant or pollutant property

kg/1,000 kkg (pounds per million pounds) of metal poured

mg/l(1)

mg/l(1)

(2)

Copper (T)

0.0527

0.0291

0.29

0.16

0.0118

Lead (T)

0.0964

0.0473

0.53

0.26

0.0273

Zinc (T)

0.178

0.0673

0.98

0.37

0.0473

(1)These concentrations shall be multiplied by the ratio of (21.8/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of metal poured) for a specific plant.

(2) kg/1,000 kkg (pounds per million pounds) of metal poured.

TABLE 54

FERROUS CASTING SUBCATEGORY

WET SAND RECLAMA TION OPERATIONS

BAT Effluent Limitations

Noncontinuous Direct Dischargers

Maximum for any 1 day

Maximum for monthly average

Maximum for any 1 day

Maximum for monthly average

Annual average

Pollutant or pollutant property

kg/1,000 kkg (pounds per million pounds) of sand reclaimed

mg/l(1)

mg/l(1)

(2)

Copper (T)

0.217

0.12

0.29

0.16

0.0485

Lead (T)

0.396

0.194

0.53

0.26

0.112

Zinc (T)

0.732

0.276

0.98

0.37

0.194

Total phenols

0.642

0.224

0.86

0.3

0.149

(1) These concentrations shall be multiplied by the ratio of (89.5/x) where x is the actual normalized process wastewater discharge flow (in gallons per 1,000 pounds of sand reclaimed) for a specific plant.

(2) kg/1,000 kkg (pounds per million pounds) of sand reclaimed.

Wis. Admin. Code Department of Natural Resources § NR 256.33

Cr. Register, June, 1989, No. 402, eff. 7-1-89.