Wis. Admin. Code ATCP § 5-402.11

Current through May 28, 2024
Section 5-402.11 - Backflow Prevention
(A) Except as specified in ¶¶ (B), (C), and (D) of this section, a direct connection may not exist between the SEWAGE system and a drain originating from EQUIPMENT in which FOOD, portable EQUIPMENT, or UTENSILS are placed. P
(B)Paragraph (A) of this section does not apply to floor drains that originate in refrigerated spaces that are constructed as an integral part of the building.
(C)If allowed by LAW, a WAREWASHING machine may have a direct connection between its waste outlet and a floor drain when the machine is located within 1.5 m (5 feet) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap.
(D)If allowed by LAW, a WAREWASHING or culinary sink may have a direct connection.

Wis. Admin. Code Department of Agriculture, Trade and Consumer Protection § 5-402.11

Adopted by,Register April 2015 No. 712, eff.5/1/2015.
Amended by,Register August 2016 No. 728, eff. 9/1/2016.
Adopted by, Register July 2020 No. 775, eff. 8/1/2020