Wash. Admin. Code § 51-50-0504

Current through Register Vol. 25-01, January 1, 2025
Section 51-50-0504 - Section 504-Building height and number of stories

Table 504.3

Allowable Building Height in Feet Above Grade Planea

Occupancy Classification

Type of Construction

See Footnotes

Type I

Type II

Type III

Type IV

Type V

A

B

A

B

A

B

A

B

C

HT

A

B

A, B, E, F, M, S, U

NSb

UL

160

65

55

65

55

65

65

65

65

50

40

S

UL

180

85

75

85

75

270

180

85

85

70

60

H-1, H-2, H-3, H-5

NSc,d

UL

160

65

55

65

55

120

90

65

65

50

40

S

H-4

NSc,d

UL

160

65

55

65

55

65

65

65

65

50

40

S

UL

180

85

75

85

75

140

100

85

85

70

60

I-1 Condition 1, I-3

NSd,e

UL

160

65

55

65

55

65

65

65

65

50

40

S

UL

180

85

75

85

75

180

120

85

85

70

60

I-1 Condition 2, I-2

NSd,e,f

UL

160

65

55

65

55

65

65

65

65

50

40

Si

UL

180

85

I-4

NSd,g

UL

160

65

55

65

55

65

65

65

65

50

40

S

UL

180

85

75

85

75

180

120

85

85

70

60

Rh

NSd

UL

160

65

55

65

55

65

65

65

65

50

40

S13D

60

60

60

60

60

60

60

60

60

60

50

40

S13R

60

60

60

60

60

60

60

60

60

60

60

60

S

UL

180

85

75

85

75

270

180

85

85

70

60

For SI: 1 foot = 304.8 mm.

UL = Unlimited; NS = Buildings not equipped throughout with an automatic sprinkler system; S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; S13R = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.3.

a See Chapters 4 and 5 for specific exceptions to the allowable height in this chapter.

b See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies.

c New Group H occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.5.

d The NS value is only for use in evaluation of existing building height in accordance with the International Existing Building Code.

e New Group I-1 and I-3 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6. For new Group I-1 occupancies Condition 1, see Exception 1 of Section 903.2.6.

f New and existing Group I-2 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6 and Section 1103.5 of the International Fire Code.

g For new Group I-4 occupancies, see Exceptions 2 and 3 of Section 903.2.6.

h New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.8.

i I-1, Condition 2 Assisted living facilities licensed in accordance with chapter 388-78A WAC and residential treatment facilities as licensed by Washington state under chapter 246-337 WAC shall be permitted to use the allowable height above grade plane for Group R-2 occupancies.

Table 504.4

Allowable Number of Stories Above Grade Planea,b

Occupancy Classification

Type of Construction

See Footnotes

Type I

Type II

Type III

Type IV

Type V

A

B

A

B

A

B

A

B

C

HT

A

B

A-1

NS

UL

5

3

2

3

2

3

3

3

3

2

1

S

UL

6

4

3

4

3

9

6

4

4

3

2

A-2

NS

UL

11

3

2

3

2

3

3

3

3

2

1

S

UL

12

4

3

4

3

18

12

6

4

3

2

A-3

NS

UL

11

3

2

3

2

3

3

3

3

2

1

S

UL

12

4

3

4

3

18

12

6

4

3

2

A-4

NS

UL

11

3

2

3

2

3

3

3

3

2

1

S

UL

12

4

3

4

3

18

12

6

4

3

2

A-5

NS

UL

UL

UL

UL

UL

UL

1

1

1

UL

UL

UL

S

UL

UL

UL

UL

UL

UL

UL

UL

UL

UL

UL

UL

B

NS

UL

11

5

3

5

3

5

5

5

5

3

2

S

UL

12

6

4

6

4

18

12

9

6

4

3

E

NS

UL

5

3

2

3

2

3

3

3

3

1

1

S

UL

6

4

3

4

3

9

6

4

4

2

2

F-1

NS

UL

11

4

2

3

2

3

3

3

4

2

1

S

UL

12

5

3

4

3

10

7

5

5

3

2

F-2

NS

UL

11

5

3

4

3

5

5

5

5

3

2

S

UL

12

6

4

5

4

12

8

6

6

4

3

H-1

NSc,d

1

1

1

1

1

1

NP

NP

NP

1

1

NP

S

1

1

1

H-2

NSc,d

UL

3

2

1

2

1

1

1

1

2

1

1

S

2

2

2

H-3

NSc,d

UL

6

4

2

4

2

3

3

3

4

2

1

S

4

4

4

H-4

NSc,d

UL

7

5

3

5

3

5

5

5

5

3

2

S

UL

8

6

4

6

4

8

7

6

6

4

3

H-5

NSc,d

4

4

3

3

3

3

2

2

2

3

3

2

S

3

3

3

I-1 Condition 1

NSd,e

UL

9

4

3

4

3

4

4

4

4

3

2

S

UL

10

5

4

5

4

10

7

5

5

4

3

I-1 Condition 2

NSd,e

UL

9

4

3

4

3

3

3

3

4

3

2

Si

UL

10

5

10

6

4

I-2

NSd,f

UL

4

2

1

1

NP

NP

NP

NP

1

1

NP

S

UL

5

3

7

5

1

I-3

NSd,e

UL

4

2

1

2

1

2

2

2

2

2

1

S

UL

5

3

2

3

2

7

5

3

3

3

2

I-4

NSd,g

UL

5

3

2

3

2

3

3

3

3

1

1

S

UL

6

4

3

4

3

9

6

4

4

2

2

M

NS

UL

11

4

2

4

2

4

4

4

4

3

1

S

UL

12

5

3

5

3

12

8

6

5

4

2

R-1h

NSd

UL

11

4

4

4

4

4

4

4

4

3

2

S13R

4

4

4

3

S

UL

12

5

5

5

5

18

12

8

5

4

3

R-2h

NSd

UL

11

4

4

4

4

4

4

4

4

3

2

S13R

4

4

4

4

3

S

UL

12

5

5

5

5

18

12

8

5

4

3

R-3h

NSd

UL

11

4

4

4

4

4

4

4

4

3

3

S13D

4

4

3

3

S13R

4

4

4

4

S

UL

12

5

5

5

5

18

12

5

5

4

4

R-4h

NSd

UL

11

4

4

4

4

4

4

4

4

3

2

S13D

4

4

3

2

S13R

4

4

4

3

S

UL

12

5

5

5

5

18

12

5

5

4

3

S-1

NS

UL

11

4

2

3

2

4

4

4

4

3

1

S

UL

12

5

4

4

4

10

7

5

5

4

2

S-2

NS

UL

11

5

3

4

3

4

4

4

5

4

2

S

UL

12

6

4

5

4

12

8

5

6

5

3

U

NS

UL

5

4

2

3

2

4

4

4

4

2

1

S

UL

6

5

3

4

3

9

6

5

5

3

2

UL = Unlimited; NP = Not permitted; NS = Buildings not equipped throughout with an automatic sprinkler system; S = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; S13R = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D = Buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.3.

a See Chapters 4 and 5 for specific exceptions to the allowable height in this chapter.

b See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies.

c New Group H occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.5.

d The NS value is only for use in evaluation of existing building height in accordance with the International Existing Building Code.

e New Group I-1 and I-3 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6. For new Group I-1 occupancies Condition 1, see Exception 1 of Section 903.2.6.

f New and existing Group I-2 occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6 and Section 1103.5 of the International Fire Code.

g For new Group I-4 occupancies, see Exceptions 2 and 3 of Section 903.2.6.

h New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.8.

i Group I-1, Condition 2 Assisted living facilities licensed in accordance with chapter 388-78A WAC and residential treatment facilities as licensed by Washington state under chapter 246-337 WAC shall be permitted to use the allowable number of stories for Group R-2 occupancies.

504.4.1Stair enclosure pressurization increase. For Group R-1, R-2, and I-1 Condition 2 Assisted living facilities licensed under chapter 388-78A WAC and residential treatment facilities as licensed by Washington state under chapter 246-337 WAC located in buildings of Type VA construction equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, the maximum number of stories permitted in Section 504.4 may be increased by one provided the interior exit stairways and ramps are pressurized in accordance with Sections 909.6.3 and 909.20. Legally required standby power shall be provided in accordance with Sections 909.11 and 2702.17 for buildings constructed in compliance with this section and be connected to stairway shaft pressurization equipment, elevators and lifts used for accessible means of egress (if provided), elevator hoistway pressurization equipment (if provided) and other life safety equipment as determined by the authority having jurisdiction. For the purposes of this section, legally required standby power shall comply with 2020 NEC Section 701.12, options (C), (D), (E), (F), (H) or (J) or subsequent revised section number(s).

Wash. Admin. Code § 51-50-0504

Amended by WSR 16-03-064, Filed 1/19/2016, effective 7/1/2016
Amended by WSR 19-02-038, Filed 12/26/2018, effective 7/1/2019
Amended by WSR 20-01-090, Filed 12/12/2019, effective 7/1/2020
Amended by WSR 20-21-021, Filed 10/9/2020, effective 11/9/2020
Amended by WSR 21-06-035, Filed 2/23/2021, effective 3/26/2021
Amended by WSR 22-13-094, Filed 6/14/2022, effective 7/1/2023
Amended by WSR 23-23-102, Filed 11/15/2023, effective 3/16/2024

Statutory Authority: RCW 19.27.031 and chapters 19.27 and 34.05 RCW. 13-04-067, § 51-50-0504, filed 2/1/13, effective 7/1/13. Statutory Authority: Chapter 19.27 RCW. 10-24-059, § 51-50-0504, filed 11/29/10, effective 7/1/11.