Wash. Admin. Code § 51-11R-40552

Current through Register Vol. 24-21, November 1, 2024
Section 51-11R-40552 - Table R405.4.2(2)-Default distribution system efficiencies for proposed designs

TABLE R405.4.2(2)

DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa

DISTRIBUTION SYSTEM CONFIGURATION AND CONDITION

DISTRIBUTION SYSTEM EFFICIENCY

Distribution system components located in unconditioned space

0.88

Distribution systems entirely located in conditioned spaceb

0.93

Zonal systemsc

1.00

For SI: 1 cubic foot per minute = 0.47 L/s, 1 square foot = 0.093m2, 1 pound per square inch = 6895 Pa, 1 inch water gauge = 1250 Pa.

a Values given by this table are for distribution systems, which must still meet all prescriptive requirements for duct and pipe system insulation and leakage.

b Entire system in conditioned space shall mean that no component of the distribution system, including the air-handler unit, is located outside of the conditioned space. All components must be located on the interior side of the thermal envelope (inside the insulation) and also inside of the air barrier. Refrigerant compressors and piping are allowed to be located outside.

c Zonal systems are systems where the heat source is located within each room. Systems shall be allowed to have forced airflow across a coil but shall not have any ducted airflow external to the manufacturer's air-handler enclosure. Hydronic systems do not qualify.

Wash. Admin. Code § 51-11R-40552

Amended by WSR 16-02-127, Filed 1/6/2016, effective 7/1/2016
Amended by WSR 23-02-060, Filed 1/3/2023, effective 7/1/2023
Amended by WSR 24-03-084, Filed 1/16/2024, effective 3/15/2024

Statutory Authority: RCW 19.27A.020, 19.27A.045 and chapters 19.27 and 34.05 RCW. 13-04-055, § 51-11R-40552, filed 2/1/13, effective 7/1/13.