Pressure measuring devices that display the pressures in the water supply line for the fresh hot water sanitizing rinse shall have increments of 1 pounds per square inch (7 kilopascals) or smaller and shall be accurate to ±2 pounds per square inch (±14 kilopascals) in the range indicated on the manufacturer's data plate.
12 Va. Admin. Code § 5-421-1200
Statutory Authority
§§ 35.1-11 and 35.1-14 of the Code of Virginia.