12 Va. Admin. Code § 5-421-1190

Current through Register Vol. 41, No. 6, November 4, 2024
Section 12VAC5-421-1190 - Temperature measuring devices; ambient air and water
A. Ambient air and water temperature measuring devices that are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be easily readable and accurate to plus or minus 1.5°C in the intended range of use.Pf
B. Ambient air and water temperature measuring devices that are scaled only in Fahrenheit shall be accurate to plus or minus 3°F in the intended range of use.Pf

12 Va. Admin. Code § 5-421-1190

Derived from Virginia Register Volume 18, Issue 10, eff. March 1, 2002; Amended, Virginia Register Volume 32, Issue 22, eff. 7/12/2016; Amended, Virginia Register Volume 37, Issue 18, eff. 6/10/2021.

Statutory Authority: §§ 35.1-11 and 35.1-14 of the Code of Virginia.