Utah Admin. Code 392-105-9

Current through Bulletin 2024-12, June 15, 2024
Section R392-105-9 - Requirements for Sanitizing Equipment and Utensils
(1) After being cleaned as required in Section R392-105-8, equipment and utensils shall be sanitized in chemical manual or mechanical operations, including the application of sanitizing chemicals by immersion, manual swabbing, brushing, or pressure spraying methods, using a solution as specified under Subsection R392-105-9(2).
(2) Chemical sanitizers, including chemical sanitizing solutions generated on-site, and other chemical antimicrobials applied to food-contact surfaces shall:
(a) meet requirements specified in 40 CFR 180.940 and 40 CFR 180.2020; and
(b) be used in accordance with the EPA-registered label use instructions.
(3) The concentration of chemical sanitizer solution shall be maintained as follows:
(a) chlorine sanitizer solutions shall have a minimum concentration and temperature of 50 to 100 ppm at 100 degrees F with an associated contact time of seven seconds; and
(b) quaternary ammonium compound solutions shall have a minimum temperature of 75 degrees F and a concentration as indicated by the manufacturer's use directions included in the labeling.
(4) When manual warewashing and sanitizing of utensils or food-contact equipment is done in an agritourism food establishment, the operator shall provide a test kit or other device that accurately measures the concentration in parts per million of chemical sanitizer solution.

Utah Admin. Code R392-105-9

Adopted by Utah State Bulletin Number 2021-02, effective 12/21/2020
Amended by Utah State Bulletin Number 2022-13, effective 6/21/2022