The summation of AFR (i)/FRSL (i) for i = 1 to n is less than or equal to 1.0
where:
n = number of carcinogenic metals
AFR = actual feed rate to the device for metal "i"
FRSL = feed rate screening limit provided by appendix I of Rule R315-266 for metal "i".
TESH = Ha+H1-Tr
where:
Ha = Actual physical stack height
H1 = Plume rise as determined from appendix VI of Rule R315-266 as a function of stack flow rate and stack gas exhaust temperature.
Tr = Terrain rise within five kilometers of the stack.
K = HVT
Where:
K = a parameter accounting for relative influence of stack height and plume rise;
H = physical stack height (meters);
V = stack gas flow rate (m3/second); and
T = exhaust temperature (deg. K).
The stack with the lowest value of K is the worst-case stack.
The summation of AER (i)/ERSL (i) for i = 1 to n is less than or equal to 1.0
where:
n = number of carcinogenic metals
AER = actual emission rate for metal "i"
ERSL = emission rate screening limit provided by appendix I of Rule R315-266 for metal "i".
The summation of Predicted Ambient Concentration (i)/Risk-Specific Dose (i) for i = 1 to n is less than or equal to 1.0
where: n = number of carcinogenic metals
Utah Admin. Code R315-266-106