6-202.11Light Bulbs, Protective Shielding.(A) Except as specified in (B) of this section, light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food, clean equipment, utensils and linens, or unwrapped single-service and single-use articles.(B) Shielded, coated, or otherwise shatter-resistant bulbs need not be used in areas used only for storing food in unopened packages, if:(1) The integrity of the packages cannot be affected by broken glass falling onto them and(2) The packages are capable of being cleaned of debris from broken bulbs before the packages are opened.(C) An infrared or other heat lamp shall be protected against breakage by a shield surrounding and extending beyond the bulb so that only the face of the bulb is exposed.6-202.12Heating, Ventilating, Air-conditioning System Vents.Heating, ventilating, and air conditioning systems shall be designed and installed so that make-up air intake and exhaust vents do not cause contamination of food, food-contact surfaces, equipment, or utensils.
6-202.13Insect Control Devices, Design, and Installation.(A) Insect control devices that are used to electrocute or stun flying insects shall be designed to retain the insect within the device.(B) Insect control devices shall be installed so that: (1) The devices are not located over a food preparation area and(2) Dead insects and insect fragments are prevented from being impelled onto or falling on exposed food, clean equipment, utensils, linens, and unwrapped single-service and single-use articles.6-202.14Toilet Rooms, Enclosed.Except where a toilet room is located outside a retail food establishment and does not open directly into the retail food establishment such as a toilet room that is provided by the management of a shopping mall, a toilet room located on the premises shall be completely enclosed and provided with a tight-fitting and self-closing door or, for a public access restroom, an alcove opening as approved by local building codes.
6-202.15Outer Openings Protected.(A) Except as specified in (B), (C), (E), and under (D) of this section, outer openings of a retail food establishment shall be protected against the entry of insects and rodents by: (1) Filling or closing the holes and other gaps along floors, walls, and ceiling;(2) Closed tight-fitting windows; and(3) Solid, self-closing, tight-fitting doors.(B) Paragraph (A) of this section does not apply if a retail food establishment opens into a larger structure, such as a mall, airport, or office building, or into an attached structure, such as a porch, and the outer openings from the larger or attached structure are protected against the entry of insects and rodents.(C) Exterior doors used as exits need not be self-closing if they are: (1) Solid and tight-fitting;(2) Designated for use, only when an emergency exists, by the fire protection authority that has jurisdiction over the retail food establishment; and(3) Limited-use so they are not used for entrance or exit from the building for purposes other than the designated emergency exit use.(D) Except as specified in (B) and (E) of this section, if the windows or doors of a retail food establishment or of a larger structure within which a retail food establishment is located, are kept open for ventilation or other purposes the openings shall be protected against the entry of insects and rodents by: (1) Sixteen (16) mesh to one (1) inch (16 mesh to 25.4 mm) screens;(2) Properly designed and installed air curtains to control flying insects; or(3) Other effective means.(E) Paragraph (D) of this section does not apply if flying insects and other pests are absent due to the location of the establishment, the weather, or other limiting conditions.6-202.16Exterior Walls and Roofs, Protective Barrier.Perimeter walls and roofs shall effectively protect the retail food establishment from the weather and the entry of insects, rodents, and other animals.
6-202.18Outdoor Servicing Areas, Overhead Protection.Except for areas used only for the loading of water or the discharge of sewage and other liquid waste through the use of a closed system of hoses, servicing areas shall be provided with overhead protection.
6-202.19Outdoor Walking and Driving Surfaces, Graded to Drain.Exterior walking and driving surfaces shall be graded to drain.
6-202.110 Outdoor Refuse Areas, Curbed and Graded to Drain.Outdoor refuse areas shall be constructed in accordance with law and shall be curbed and graded to drain to collect and dispose of liquid waste that results from the refuse and from cleaning the area and waste receptacles.
6-202.111Private Residence and Living or Sleeping Quarters, Use Prohibition.A private home, a room used as living or sleeping quarters, or an area directly opening into a room used as living or sleeping quarters may not be used for conducting retail food establishment operations. P
6-202.112Living or Sleeping Quarters, Separation.Living or sleeping quarters located in the premises of a retail food establishment, such as those provided for lodging registration clerks or resident managers, shall be separated from rooms and areas used for retail food establishment operations by complete partitioning and solid self-closing doors.
S.C. Code Regs. § 61-25.6-202
Replaced and amended by State Register Volume 38, Issue No. 6, eff 6/27/2014; State Register Volume 43, Issue No. 05, eff. 5/24/2019.