Process Operations for which Permissible Emission Rate is Based on Process Weight: | |
a. | 'Reserved' |
b. | Expanded aggregate kilns (lightweight aggregate plants) |
c. | Continuous process material dryers emitting solid particulates and water only |
d. | Brass and bronze melting furnaces |
e. | Ferro alloy production furnaces |
f. | Lime kilns |
g. | Glass production furnaces |
h. | Graphitizing and silicon carbide furnaces |
i. | Gypsum dryers |
j. | Primary aluminum reduction pot lines |
Process weight per hour (lb/hr) | Permissible emission rate (lb/hr) | |
Existing emission source* | New emission source or modification | |
100 | 0.52 | 0.52 |
500 | 1.5 | 1.5 |
1,000 | 2.5 | 2.5 |
5,000 | 7.2 | 7.2 |
10,000 | 11.5 | 11.5 |
25,000 | 20.2 | 20.2 |
50,000 | 33.8 | 33.8 |
75,000 | 44.3 | 44.3 |
100,000 | 53.7 | 53.7 |
250,000 | 58.1 | 0.030 grain per standard cubic foot of undiluted exhaust gas on a dry basis |
500,000 | 64.4 | |
750,000 | 68.3 | |
1,000,000 | 71.1 | |
2,000,000 | 78.2 | |
5,000,000 | 88.2 |
* Existing emission sources are ones for which applications for permits were received prior to July 1, 1973
To determine values of permissible emission rate not shown in table:
For all process weight sources up to 100,000 lb/hr, use E = 0.024P0.67
For existing process weight sources in excess of 100,000 lb/hr, use
E = (39P0.082)- 50 where E = permissible emission rate; P = process weight in lb/hr.
N.Y. Comp. Codes R. & Regs. Tit. 6 §§ 212-2.5