Section Env-A 904.08 - Recordkeeping for Sources or Devices with Add-on VOC Air Pollution Control Equipment The owner or operator of any stationary source, area source, or device with add-on VOC control equipment shall maintain records of the following information, as applicable:
(a) The air pollution control device identification number, type, model number, and manufacturer;(c) Process(es) or device(s) controlled;(d) The type and location of the capture system, capture efficiency percentage, and method of determining capture efficiency;(e) Information as to whether or not the control device is always in operation when the process(es) or device(s) are in operation;(f) The destruction or removal efficiency of the add-on air pollution control equipment, including: (1) Destruction or removal efficiency, in percent;(3) The emission test results, if tested, including:a. The inlet VOC concentration in ppm;b. The outlet VOC concentration in ppm; andc. The method of determination of the concentrations in a. and b. above; and(4) The method of determining destruction or removal efficiency, if not tested;(g) For thermal incinerators, the design combustion temperature in degrees F;(h) For catalytic incinerators: (1) The design exhaust gas temperature in degrees F;(2) The design temperature rise across the catalyst bed in degrees F;(3) The anticipated frequency of catalyst change; and(4) Any actual catalyst changes;(i) For a condenser: (1) The design inlet temperature of the cooling medium; and(2) The design exhaust gas temperature in degrees F; and(j) For a carbon adsorber: (1) The design pressure drop across the adsorber; and(2) The VOC concentration at breakthrough.N.H. Code Admin. R. Env-A 904.08
Derived From Volume XXXV Number 32, Filed August 13, 2015, Proposed by #10892, Effective 7/18/2015, Expires7/18/2025.