N.H. Code Admin. R. Env-A 904.07

Current through Register No. 25, June 20, 2024
Section Env-A 904.07 - VOC Recordkeeping for Fixed Roof or External Floating Roof VOL Storage Tanks, Bulk Gasoline Loading Terminals, Bulk Storage Plants, and Petroleum Refineries

For fixed-roof or external floating-roof volatile organic liquid (VOL) storage tanks, bulk gasoline loading terminals, bulk storage plants, and petroleum refineries that are subject to Env-A 1217, the owner or operator shall maintain records of the following information:

(a) Individual VOL storage tank data, if applicable, including the following:
(1) Tank capacity;
(2) Volume and type of VOL stored;
(3) For VOL storage tanks, a record of the maximum true vapor pressure of the liquid as stored;
(4) For VOL storage tanks exempted by Env-A 1217.01(a) or Env-A 1217.03(a), but containing a VOL with a true vapor pressure greater than 7.0 kilopascals (kPa), or 1.0 pound per square inch atmospheric (psia):
a. Average monthly storage temperature;
b. Type of liquid stored; and
c. Maximum true vapor pressure for any VOL with a true vapor pressure exceeding 7.0 kPa (1.0 psia); and
(5) Air pollution control equipment information including;
a. For VOL storage tanks, seal type, and date of retrofit, if applicable; and
b. For VOL storage tanks, records of malfunctions, visual leak inspection results, including:
1. For fixed-roof tanks, reports and results of inspections conducted in accordance with Env-A 1217.02(f) and Env-A 1217.02(g); and
2. For external floating roof tanks, reports and results of inspections conducted in accordance with Env-A 1217.04(j) and Env-A 1217.04(k);
(b) Records of VOC emission testing and all continuous emission monitoring data, including, for bulk gasoline loading terminals, records that document compliance with the emission limit pursuant to Env-A 1217.06(a); and
(c) For petroleum refineries:
(1) Records of malfunctions, visual leak inspection results, startups, and shutdowns;
(2) Records of VOC emission testing and all continuous emission monitoring data;
(3) Each date that any process unit or vessel was shut down; and
(4) The vessel volatile organic compound concentration when the volatile organic compounds were first discharged to the atmosphere.

N.H. Code Admin. R. Env-A 904.07

#6983-B, eff 4-23-99 (formerly Env-A 901.06); ss by #8872, eff 4-21-07

Amended by Volume XXXV Number 32, Filed August 13, 2015, Proposed by #10892, Effective 7/18/2015, Expires7/18/2025.