N.H. Code Admin. R. Env-A 3210.08

Current through Register No. 25, June 20, 2024
Section Env-A 3210.08 - Out of Control Periods
(a) Whenever any monitoring system fails to meet the quality assurance requirements of 40 CFR 75, appendix B, data shall be substituted using the applicable procedures in 40 CFR 75, Subpart D, appendix D or appendix E.
(b) Whenever both an audit of a monitoring system and a review of the initial certification or recertification application reveal that any system or component should not have been certified or recertified because it did not meet a particular performance specification or other requirement under this part or the applicable provisions of 40 CFR Part 75, both at the time of the initial certification or recertification application submission and at the time of the audit, the department shall issue a notice of disapproval of the certification status of such system or component.
(c) For the purposes of this section, an audit shall be either a field audit or an audit of any information submitted to the department or the administrator.
(d) The data measured and recorded by the system or component shall not be considered valid quality-assured data from the date of issuance of the notification of the disapproval of certification status until the date and time that the owner or operator completes subsequently approved initial certification or recertification tests in accordance with Env-A 3210.05(s).
(e) The owner or operator shall follow the initial certification or recertification procedures for each disapproved system.

N.H. Code Admin. R. Env-A 3210.08

Derived From Volume XXXVI Number 01, Filed January 7, 2016, Proposed by #11001, Effective 1/1/2016, Expires 1/1/2026.