Section Env-A 1404.04 - In-stack Concentration Method

If the in-stack concentration method is selected, the owner or operator shall use the following equations to calculate that the emissions of each RTAP is equal to or below the corresponding AAL, where:

(a) "X" means:
(1) For devices or processes emitting from one stack, the emission rate of each RTAP in pounds per hour (lbs/hr); or
(2) For devices or processes emitting from more than one stack, the sum of emission rates of each RTAP from each stack in lbs/hr;
(b) "Y" means the emission rate of each RTA Pin grams per second (g/sec) as determined by dividing X by 7.94, as shown in the formula below:

Click here to view image

(c) "Z" means the emission rate of each RTAP in micrograms per second (µg/sec) as determined by multiplying Y by 10, as shown in the formula below:

Click here to view image

(d) "A" means:
(1) For devices or processes emitting from one stack, the stack volume flow in actual cubic feet per minute (ft/min); or
(2) For devices or processes emitting from more than one stack, the sum of stack volume flows from each stack in actual ft/min;
(e) "B" means the stack volume flow in actual cubic meters per second (m/sec) as determined by dividing A by 2119, as shown in the formula below:

Click here to view image

(f) The in-stack concentration of each RTAP in micrograms per cubic meter (µg/m) from a device or process either emitting from a single stack or from more than one stack shall be calculated by dividing Z by B, as shown in the formula below:

Click here to view image

N.H. Code Admin. R. Env-A 1404.04

Derived from Volume XLII Number 6, Filed February 10, 2022, Proposed by #13334, Effective 2/3/2022, Expires 2/3/2032 (formerly Env-A 1405.04).