Section 534.4359 - Monitoring wells: Measures required if contaminant or contaminated water is encountered

If a contaminant or contaminated water is encountered during the construction of a monitoring well, the strata which contain the contaminant or contaminated water must be cased and sealed in such a manner that the contaminant or contaminated water does not commingle with or impair other strata or the water contained in other strata. The well driller shall seal the strata by grouting or by using special seals or packers, if necessary, to prevent the movement of the contaminants or contaminated water in the borehole.

Nev. Admin. Code § 534.4359

Added to NAC by St. Engineer, eff. 12-30-97; A by R068-20A, eff. 12/29/2020; A by R068-20CAP, eff. 6/23/2021