Nev. Admin. Code § 461A.220

Current through December 12, 2024
Section 461A.220 - Supply of fuel
1. A system for supplying natural gas or liquefied petroleum gas to mobile homes and other structures within a mobile home park must be designed, constructed and repaired in accordance with state and federal law.
2. A system for supplying oil to mobile homes and other structures within a mobile home park must be installed in accordance with state and federal law.
3. If gas is to be supplied through an underground system, the connection at each mobile home stand must be located and arranged to permit attachment in a workmanlike manner to a mobile home occupying the mobile home stand. The riser for supplying gas to a mobile home must be located no less than 18 inches and not more than 4 feet from the mobile home stand.

Nev. Admin. Code § 461A.220

Added to NAC by Mfd. Housing Div., eff. 6-29-84; A by R055-02, 7-18-2002

NRS 461A.090, 461A.230