The owner or operator of a Class I waste combustor must comply with the emission limits, notification, monitoring, testing, record-keeping, and reporting requirements of the new source performance standards incorporated in parts 7011.1291 to 7011.1294, except as provided in subpart 2. In addition, the owner or operator must comply with:
Instead of the mercury emission limits contained in Code of Federal Regulations, title 40, sections 60.52b(a)(5), 60.58b(d)(2)(ix), and 60.58b(d)(2)(x), as amended, the owner or operator of a Class I waste combustor must comply with the mercury emission limits described in this subpart and the testing and reporting requirements of parts 7011.1265, subpart 2; and 7011.1270, item E.
Class I | |
Mercury (short-term) | |
For all waste combustors except those combusting RDF in spreader stokers | 80 µg/dscm or 85% removal |
Waste combustor units combusting RDF in spreader stokers (90-day test interval) | 50 µg/dscm or 85% removal |
Mercury (long-term) | |
For all waste combustors except those combusting RDF in spreader stokers | 60 µg/dscm or 85% removal |
Waste combustor units combusting RDF in spreader stokers (90-day test interval) | 30 µg/dscm or 85% removal |
Waste combustor units combusting RDF in spreader stokers (12-month test interval) | 30 µg/dscm or 85% removal |
Minn. R. agency 167, ch. 7011, WASTE COMBUSTORS, pt. 7011.1230
Statutory Authority: MS s 116.07