Mich. Admin. Code R. 408.10605

Current through Vol. 24-21, December 1, 2024
Section R. 408.10605 - Definitions; N to S

Rule 605.

(1) "Nationally recognized testing laboratory." See 29 C.F.R. A§ 1910.7"Definition and requirements for a nationally recognized testing laboratory," as adopted in R 408.10606, for the definition.
(2) "Noncombustible building" means a building that is constructed of materials that do not support fire.
(3) "Occupant load" means the total number of persons that may occupy a workplace or portion of a workplace at any one time. The occupant load of a workplace is calculated by dividing the gross floor area of the workplace or portion of the workplace by the occupant load factor for that particular type of workplace occupancy. Information regarding the "Occupant load" is located in NFPA 101 "Life Safety Code," 2009 edition and in the "International Fire Code" 2009 edition, as adopted in R 408.10606.
(4) "Ordinary hazard contents" means combustibles that are liable to burn with moderate rapidity and to give off a considerable volume of smoke, but from which neither extremely poisonous fumes nor explosions are to be expected in case of fire.
(5) "Refuge area" means either of the following:
(a) A space along an exit route that is protected from the effects of fire by separation from other spaces within the building by a barrier with at least a 1-hour fire resistance-rating.
(b) A floor with at least 2 spaces, separated from each other by smoke-resistant partitions, in a building protected throughout by an automatic sprinkler system that complies with General Industry Safety Standard Part 9 "Fixed Fire Equipment," as referenced in R 408.10606.
(6) "Self-closing" means equipped with an approved device which will ensure closing without manual assistance after having been opened.
(7) "Sprinklered" means equipped with an approved automatic sprinkler system that is properly maintained.
(8) "Street" means a public thoroughfare that is 30 or more feet in width, that has been dedicated or deeded to the public for public use, and that is accessible for use by a fire department in fighting fires. An enclosed space or tunnel, even though used for vehicular and pedestrian traffic, is not considered a street.
(9) "Self-luminous" means a light source that is illuminated by a self-contained power source, like tritium, and that operates independently from external power sources. Batteries are not acceptable self-contained power sources. The light source is typically contained inside the device.
(10) "Surface bolt" means a locking bolt that is installed on the surface of a door.

Mich. Admin. Code R. 408.10605

1979 AC; 1990 AACS; 2015 MR 8, Eff. April 29, 2015