Section 10.15.03.18 - Control of Sanitary FacilitiesThe person-in-charge shall ensure that:
A. Potable water is: (1) Obtained from a water supply system that complies with Environment Article, Title 9, Annotated Code of Maryland, and COMAR 26.04.04; and(2) Meets the standards of quality specified in Environment Article, Title 9, Annotated Code of Maryland, and COMAR 26.04.01;B. Non-potable water for non-culinary purposes such as air conditioning or fire protection is used only if the system complies with §H(3) of this regulation;C. Except for a temporary food service facility where water under pressure is not available, hot and cold running water under pressure is provided:(1) In all areas where:(a) Food is prepared; and(b) Equipment and utensils are washed; and(2) With sufficient water capacity, pressure, and hot water generation and distribution to meet peak demands throughout the facility;D. Drinking water, if not dispensed through the water supply system of the food service facility, is potable and stored in a container that meets all applicable laws, ordinances, and regulations;E. Steam that contacts food is free from deleterious or harmful matter that might adulterate food;F. All water-carried sewage is disposed of by: (1) A public sewerage system; or(2) An approved sewage disposal system constructed and operated in conformance with applicable State and local laws, ordinances, and regulations;G. Where water-carried disposal methods are not possible, non-water-carried sewage disposal facilities are utilized if: (1) The method has been approved by the approving authority as meeting State and local requirements; and(2) The facilities are: (a) In conformance with applicable State and local laws, ordinances, and regulations; and(b) Located outside and not attached to the establishment;H. Plumbing is sized, installed, and maintained so that: (1) The plumbing complies with applicable State and local plumbing laws, ordinances, and regulations;(2) The potable water supply system is: (a) Installed in a manner that prevents backflow or backsiphonage; and(b) Not connected with a non-potable water system in a manner that would allow non-potable water to be drawn or discharged into the potable water supply system;(3) The piping of a non-potable water system is: (a) Marked so that the piping is readily distinguishable from piping that carries potable water, such as with distinctive yellow-colored paint; and(b) Not connected to equipment or other outlets in the food preparation area;(4) Indirect waste piping is provided to a: (a) Food preparation or utensil washing sink;(e) Coffee urn or brewer;(f) Hot or cold drink machine;(i) Warewashing machine, unless: (i) The machine is located within 5 feet of a trapped floor drain; and(ii) The waste piping is connected directly to the inlet side of a floor drain trap vented in conformance with applicable State and local laws, ordinances, and regulations; and(j) Similar piece of equipment in which food, portable equipment, or utensils are placed;(5) Each compartment of a multiple compartment sink is indirectly drained to a trapped and vented plumbing receptor through an air gap that complies with State and local laws, regulations, and ordinances:(a) From a separate pipe through the air gap and into the plumbing receptor; or(b) Through the air gap into a single manifolded branch and into the plumbing receptor;(6) Plumbing receptors receiving the discharge of indirect waste pipes:(a) Have a shape and capacity that will prevent splashing or flooding; and(b) Are accessible for cleaning and inspection;(7) Food waste grinders are connected and trapped separately from other fixtures or sink compartments;(8) Floor drains subject to evaporation have:(a) A water seal of at least 4 inches;(b) Water fed from a plumbing fixture that complies with State and local laws, regulations, and ordinances; or(c) An automatic priming device that complies with State and local laws, regulations, and ordinances;(9) Floor drains in storerooms, refrigerated rooms, walk-in coolers, or other locations where food is stored, have indirect waste piping;(10) Hand sinks in food preparation tables and counters discharge through an air gap into a floor sink or receptor that is trapped and vented; and(11) Except when required by building design, waste pipes and fixtures are: (a) Not located over food storage, preparation, or serving areas; and(b) Where installed over food storage, preparation, or serving areas, food is protected by one or more of the following: (i) Pipe joining methods that will preclude leakage;(ii) Using wall-mounted fixtures;(iii) Limiting the number of pipe joints;(iv) Pressure testing the piping;(v) Thermally insulating pipes to prevent condensation; and(vi) Installing integral seepage pans or pipe sleeves;I. Toilet facilities are: (1) Sufficient in number to serve the facility;(2) Conveniently located;(3) Accessible to employees at all times;(4) Except as specified in Health-General Article, §21-325(b), Annotated Code of Maryland, for facilities established after January 1, 1979, provided for patrons whenever a food service facility: (a) Prepares food and provides seating; or(b) Is a carry-out facility with indoor tables used for dining;(5) Installed in accordance with applicable State and local laws, ordinances, and regulations;(6) Designed with fixtures that are: (a) Of sanitary design; and(7) Kept: (c) Free of objectionable odor; and(8) Supplied with: (a) Toilet tissue at each toilet at all times; and(b) Receptacles that are easily cleanable and covered for waste materials in toilet rooms for women;J. Toilet rooms: (1) Are completely enclosed;(2) Are equipped with self-closing doors except when a toilet room without doors is approved by the approving authority based on a review that shows that: (a) Doors would impede the use of the toilet room; and(b) The requirements in §J(3)-(6) of this regulation are met;(4) Are provided mechanical ventilation that: (a) Exhausts air at the rate of 2 cubic feet per minute per square foot of floor area; and(b) Allows the entrance of an equal amount of makeup air;(5) Prevent the entry of insects and vermin; and(6) Do not open directly into the kitchen or food preparation areas;K. Hand washing facilities are: (1) Located: (a) In each food preparation and processing area;(b) In each utensil washing area; and(c) Adjacent to all toilet rooms;(2) Accessible at all times;(3) Equipped with an adequate supply of hand-cleaning soap or detergent;(4) Equipped with a means of drying hands, such as:(a) Individual towels in dispensers; or(b) An effective hand-drying device;(5) Equipped with a waste receptacle; and(6) Kept clean and in good repair;L. Hand sinks are: (1) Installed in accordance with applicable State and local laws, ordinances, and regulations;(2) Able to discharge: (a) Hot and cold running water; or(b) Tempered running water at a temperature of at least 100°F through:(ii) A combination faucet; or(iii) Any slow closing or metering faucet that provides a flow of water for at least 15 seconds before the faucet has to be reactivated; andM. Utensil washing vats, food preparation sinks, or mop sinks are not used as hand sinks.Md. Code Regs. 10.15.03.18
Regulations .18 adopted effective March 4, 1991 (18:4 Md. R. 447)
Regulation .18A amended effective February 15, 1993 (20:3 Md. R. 259)
Regulations .18 adopted effective December 17, 2007 (34:25 Md. R. 2211)
Regulation .18H, I amended effective March 19, 2010 (37:4 Md. R. 341)