La. Admin. Code tit. 43 § XIII-1164

Current through Register Vol. 50, No. 9, September 20, 2024
Section XIII-1164 - Instrument, Control, and Sampling Pipe and Components [49 CFR 192.204]
A. Riser designs must be tested to ensure safe performance under anticipated external and internal loads acting on the assembly. [49 CFR 192.204(a)]
B. Factory assembled anodeless risers must be designed and tested in accordance with ASTM F1973-13 (incorporated by reference, see § 507). [49 CFR 192.204(b)]
C. All risers used to connect regulator stations to plastic mains must be rigid and designed to provide adequate support and resist lateral movement. Anodeless risers used in accordance with this Section must have a rigid riser casing. [49 CFR 192.204(c)]

La. Admin. Code tit. 43, § XIII-1164

Promulgated by the Department of Natural Resources, Office of Conservation, LR 461584 (11/1/2020).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.