675 Ind. Admin. Code 14-4.4-210

Current through November 6, 2024
Section 675 IAC 14-4.4-210 - Section E3705.3; adjustment factor for conductor proximity

Authority: IC 22-13-2-2; IC 22-13-2-2.5; IC 22-13-2-13

Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15; IC 36-7

Sec. 210.

Add a fifth exception to the EXCEPTIONS of SECTION E3705.3 to read as follows:

5. Adjustment factors shall not apply to bundled cables ran in bored holes, or cut notches in joists or interior walls in dwellings where all of the following conditions are met:
5.1. Where these cables are run in bored holes in a wall, floor, or ceiling space and where the ambient temperature will not exceed 86°F (30°C) in normal use.
5.2. Larger than 15 and 20 ampere circuits shall not be permitted.
5.3. Where surrounded by thermal insulation, Table E3705.3 shall be followed.

675 IAC 14-4.4-210

Fire Prevention and Building Safety Commission; 675 IAC 14-4.4-210; filed 11/26/2019, 11:43 a.m.: 20191225-IR-675190330FRA