Authority: IC 22-13-2-2; IC 22-13-2-2.5; IC 22-13-2-13
Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15; IC 36-7
Sec. 178.
Change the text of SECTION P3007.3.5 to read as follows:
Pumps connected to the drainage system shall connect to building drain, soil stack, waste stack, or horizontal branch drain.
Where the discharge line connects into horizontal drainage piping, the connection shall be made through a wye fitting into the top of the drainage piping and such wye fitting shall be located not less than 10 pipe diameters from the base of any soil stack, waste stack, or fixture drain.
675 IAC 14-4.4-178