675 Ind. Admin. Code 14-4.4-15

Current through May 29, 2024
Section 675 IAC 14-4.4-15 - Section R311.3.2; floor elevations at other exterior doors

Authority: IC 22-13-2-2; IC 22-13-2-2.5; IC 22-13-2-13

Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15; IC 36-7

Sec. 15.

Change SECTION R311.3.2 as follows:

(1) Change the text of SECTION R311.3.2 to read as follows:

Doors other than the required egress door shall be provided with landings or floors not more than one stair riser below the top of the threshold.

(2) Change the text of the EXCEPTION of SECTION R311.3.2 to read as follows:

A top landing is not required for the stairway located on the exterior side of the door, provided that the threshold of the door is not more than 30" above the adjacent and the door does not swing over the stairway.

675 IAC 14-4.4-15

Fire Prevention and Building Safety Commission; 675 IAC 14-4.4-15; field 11/26/2019, 11:43 a.m.: 20191225-IR-675190330FRA