Current through November 6, 2024
Section 410 IAC 7-24-360 - Inspection and cleaning port; protected and securedAuthority: IC 16-42-5-5
Affected: IC 16-42-5
Sec. 360.
(a) If a water tank is designed with an access port for inspection and cleaning, the opening shall be in the top of the tank and as follows: (1) Flanged upward at least one-half (1/2) inch.(2) Equipped with a port cover assembly that is as follows: (A) Provided with a gasket and a device for securing the cover in place.(B) Flanged to overlap the opening and sloped to drain.(b) For purposes of this section, a violation of subsection (a) is a noncritical item.Indiana State Department of Health; 410 IAC 7-24-360; filed Oct 13, 2004, 12:30 p.m.: 28 IR 890; readopted filed Jul 15, 2010, 12:12 p.m.: 20100728-IR-410100261RFAReadopted filed 11/10/2016, 8:45 a.m.: 20161207-IR-410160371RFAReadopted filed 9/15/2022, 10:01 a.m.: 20221012-IR-410220206RFA