Complete load path and uplift ties

Section 1705.11.1 is amended to read as follows:

"1705.11.1 Complete Load Path and Uplift Ties. Metal connectors, anchors, or fasteners for wood and cold-formed steel construction at the following locations: roof ridges, roof rafters to beam or wall supports, beams to posts, posts or walls to floor framing or foundation below, ground anchors, and all other connections that are part of the load path to resist uplift forces.

Continuous special inspection is required during field gluing operations of elements of the main windforce-resisting system.

The special inspector need not be present during the installation of all of the connectors, provided that the special inspector verifies that all of the connectors are installed in conformance with the requirements of this code.