Strike Table 604.4 in the International Plumbing Code in its entirety and insert new Table 604.4 in the Plumbing Code in its place to read as follows:
TABLE 604.4
MAXIMUM FLOW RATES AND CONSUMPTION FOR
PLUMBING FIXTURES AND FIXTURE FITTINGS
PLUMBING FIXTURE OR FIXTURE FITTING | MAXIMUM FLOW RATE OR QUANTITYb |
Lavatory and bar sink faucet, private | 1.5 gpm at 60psi and WaterSense labeled |
Lavatory, public (metering) | 0.25 gallon per metering cycle |
Lavatory, public (other than metering) | 0.5 gpm at 60 psi |
Bar sink faucet in other than dwelling units or hotel and hospital private rooms | 2.2 gpm at 60 psi |
Shower heada | 2.0 gpm at 80psi and WaterSense labeled |
Sink faucet, kitchen | 2.2 gpm at 60 psi |
Urinal, flushing or non-water | 0.5 gallon per flushing cycle and WaterSense labeled, or non-water urinals |
Water closet, public and remoted | 1.6 gallons per flushing cycle |
Water closet (tank type)c | 1.28 gallons per flushing cycle and WaterSense labeled |
Water closet, private flushometer type, or public and non-remote | 1.28 gallons per flushing cycle |
For SI: 1 gallon per minute = 3.785 L/m,
1 pound per square inch = 6.895 kPa
D.C. Mun. Regs. tit. 12, r. 12-F604