Current through Register Vol. 28, No. 7, January 1, 2025
Section 4-501.110 - Mechanical Warewashing Equipment, Wash Solution Temperature(A) The temperature of the wash solution in spray type warewashers that use hot water to SANITIZE may not be less than: (1) For a stationary rack, single temperature machine, 74°C (165°F);Pf(2) For a stationary rack, dual temperature machine, 66°C (150°F);pf(3) For a single tank, conveyor, dual temperature machine, 71°C(160°F);pfor(4) For a multitank, conveyor, multitemperature machine, 66°C(150°F).pf(B) The temperature of the wash solution in spray-type warewashers that use chemicals to SANITIZE may not be less than 49°C(120°F).pf16 Del. Admin. Code § 4-501.110
17 DE Reg. 1084( 5/1/2014) (Final)