Neutron Flux Dose Equivalents
Neutron energy (Mev) | Number of neutrons per square centimeter equivalent to a dose of 1 rem (neutrons/cm2) | Average Flux to deliver 100 millirem in 40 hours (neutrons/cm2per sec.) | |
Thermal | . . . . . . . . | 970 x 106 | 670 |
0.0001 | . . . . . . . . | 720 x 106 | 500 |
0.005 | . . . . . . . . | 820 x 106 | 570 |
0.02 | . . . . . . . . | 400 x 106 | 280 |
0.1 | . . . . . . . . | 120 x 106 | 80 |
0.5 | . . . . . . . . | 43 x 106 | 30 |
1.0 | . . . . . . . . | 26 x 106 | 18 |
2.5 | . . . . . . . . | 29 x 106 | 20 |
5.0 | . . . . . . . . | 26 x 106 | 18 |
7.5 | . . . . . . . . | 24 x 106 | 17 |
10 | . . . . . . . . | 24 x 106 | 17 |
10 to 30 | . . . . . . . . | 14 x 106 | 10 |
Maximum time between collection and measurement (hours)1 | Alpha-emitting daughter activity collected per milliliter of air | ||
Microcuries/cc | Total alpha disintegrations per minute per cc. | ||
0.5 | . . . . . . . . . . . | 7.2 x 10-8 | 0.16 |
1 | . . . . . . . . . . . | 4.5 x 10-8 | 0.10 |
2 | . . . . . . . . . . . | 1.3 x 10-8 | 0.028 |
3 | . . . . . . . . . . . | 0.3 x 10-8 | 0.0072 |
1The duration of sample collection and the duration of measurement should be sufficiently short compared to the time between collection and measurement, as not to have a statistically significant effect upon the results.
Conn. Agencies Regs. § 19-24-4