While it is the intent of 974 CMR 4.05 to provide a local complaint mechanism for receptors that might be experiencing nuisance from the generation of noise or vibration, it is recognized that complaints can often be minimized by identifying and acting upon potential problems before they become contentious. For this reason, the complaint mechanism is supplemented and enhanced by a process described below which attempts to minimize or preclude potential noise and vibration issues at the time of application for site plan approval with respect to facilities in proximity to the perimeter boundary of the DEZ or at the time of application for a building permit with respect to facilities that have the potential of exceeding the performance standards within the DEZ.
Once there is reasonable certainty of the interference source, the violator shall be subject to providing reasonable mitigation measures that essentially resolve the difficulty. Refer to 974 CMR 4.05(2)(b) for a description of procedures relative to enforcement.
No party owning, leasing or otherwise controlling a facility within the DEZ shall be allowed to:
1/3 Octave Band mid Frequency adjacent (Hz) | Amount by which the average of both adjacent bands is exceeded | 1/3 Octave Band mid Frequency (Hz) | Amount by which the average of both bands is exceeded |
100 | 16 | 1250 | 4 |
125 | 14 | 1600 | 4 |
160 | 12 | 2000 | 3 |
200 | 11 | 2500 | 3 |
250 | 9 | 3150 | 3 |
315 | 8 | 4000 | 3 |
400 | 7 | 5000 | 4 |
500 | 6 | 6300 | 4 |
630 | 6 | 8000 | 5 |
800 | 5 | 10000 | 6 |
1000 | 4 |
974 CMR, § 4.05