780 CMR, ch. 34, pt. 1, 307, 308.2

Current through Register 1538, January 3, 2025
Subsection 308.2 - Change in Occupancy Classification to R, I, or E-Use

Notwithstanding other requirements in 780 CMR 34.00, see applicable provisions of 527 CMR 1.00 for certain carbon monoxide detection requirements when a change of occupancy classification to R, I, or E-Use occurs.

Add following sections.

405.1.1Repairs to structural concrete. Repairs to structural concrete elements in accordance with this section and ACI 562 shall be permitted. The evaluation, design of repairs to earthquake damage, or rehabilitation of elements of the seismic force-resisting systems shall be in compliance with section 304.3.
405.2.1.2Repairs for Less than Substantial Damage due to Snow Load Effects. Damaged roof framing components that have sustained less than substantial structural damage caused by or related to snow load effects shall be rehabilitated to comply with the applicable provisions for dead and snow loads in 780 CMR 16.00. Undamaged roof framing components that receive dead or snow loads from rehabilitated components shall also be rehabilitated to comply with the design loads of the rehabilitated design.

780 CMR, ch. 34, pt. 1, 307, 308.2

Amended by Mass Register Issue 1532, eff. 10/11/2024.