40 C.F.R. § 63 app Table 3 to Subpart HHHHHHH of Part 63

Current through May 31, 2024
Appendix Table 3 to Subpart HHHHHHH of Part 63 - Summary of Control Requirements for Storage Vessels at New and Existing Sources

If the storage vessel capacity (gallons) is . . .And the vapor pressurea (psia)
is . . .
Then, you must use the following type of storage vessel . . .
[GREATER THAN EQUAL TO]20,000 but [LESS THAN]40,000[GREATER THAN EQUAL TO]4Internal floating roof, external floating roof, or fixed roof vented to a closed vent system and control device achieving 95 percent reduction.b
[GREATER THAN EQUAL TO]40,000[GREATER THAN EQUAL TO]0.75Internal floating roof, external floating roof, or fixed roof vented to a closed vent system and control device achieving 95 percent reduction.b
Any capacity.[GREATER THAN]11.1Pressure vessel.c
All other capacity and vapor pressure combinationsFixed roof.d

a Maximum true vapor pressure of total HAP at storage temperature.

b If using a fixed roof storage vessel vented to a closed vent system and control device, you must meet the requirements in § 63.11910(a) for fixed roof storage vessels. If using an internal floating roof storage vessel or external floating roof storage vessels, you must meet the requirements in § 63.11910(b) for internal floating roof storage vessels or external floating roof storage vessels, as applicable.

c Meeting the requirements of § 63.11910(c) for pressure vessels.

d Meeting the requirements in § 63.11910(a) for fixed roof storage vessels.

40 C.F.R. 63 app Table 3 to Subpart HHHHHHH of Part 63