40 C.F.R. § 63.1662-63 app Table 5 to Subpart HHHHH of Part 63

Current through May 31, 2024
Appendix Table 5 to Subpart HHHHH of Part 63 - Emission Limits and Work Practice Standards for Transfer Operations

As required in § 63.8025 , you must meet each emission limit and work practice standard in the following table that applies to your transfer operations.

For each . . .You must. . . .
1. Group 1 transfer operation vent streama. Reduce emissions of total organic HAP by [GREATER THAN EQUAL TO]75 percent by weight by venting emissions through a closed-vent system to any combination of control devices (except a flare); or
b. Reduce emissions of total organic HAP by venting emissions from a non-halogenated vent stream through a closed-vent system to a flare; or
c. Use a vapor balancing system designed and operated to collect organic HAP vapors displaced from tank trucks and railcars during loading and route the collected HAP vapors to the storage tank from which the liquid being loaded originated or to another storage tank connected by a common header.
2. Halogenated Group 1 transfer operation vent stream for which you use a combustion device to control organic HAP emissionsa. Use a halogen reduction device after the combustion device to reduce emissions of hydrogen halide and halogen HAP by [GREATER THAN EQUAL TO]95 percent by weight or to [LESS THAN EQUAL TO]0.45 kg/hr; or
b. Use a halogen reduction device before the combustion device to reduce the halogen atom mass emission rate to [LESS THAN EQUAL TO]0.45 kg/hr.

40 C.F.R. 63.1662-63 app Table 5 to Subpart HHHHH of Part 63