As required in § 63.8020 , you must meet each emission limit and work practice standard in the following table that applies to your wastewater streams.
For each . . . | You must . . . |
1. Wastewater tank used to store a Group 1 wastewater stream | Maintain a fixed roof, which may have openings necessary for proper venting of the tank, such as pressure/vacuum vent or j-pipe vent. |
2. Group 1 wastewater stream | a. Convey using hard-piping and treat the wastewater as a hazardous waste in accordance with 40 CFR part 264, 265 , or 266 either onsite or offsite; or |
b. If the wastewater contains [LESS THAN]50 ppmw of partially soluble HAP, you may elect to treat the wastewater in an enhanced biological treatment system that is located either onsite or offsite. |
40 C.F.R. 63.1662-63 app Table 4 to Subpart HHHHH of Part 63