Temperature Accuracy. Within 1 degree F., plus or minus, between 142 degrees and 145 degrees.
Time Accuracy. The recorded elapsed time as indicated by the chart rotation must not exceed the time elapsed as indicated by a correct timepiece over a period of at last 30 minutes.
The smallest temperature scale division must not be greater than one degree between 140 degrees and 145 degrees F.
The width of the scale division between 142 degrees and 145 degrees F. must not be less than one-sixteenth of an inch.
The radial lines that indicate the time must not be closer than one-fourth inch between 142 degrees and 145 degrees F. and represent not more than 10 minutes.