The luminous intensity of a running lamp tested as specified in Article 4 of this subchapter, and with a reaim tolerance of 0.25 deg allowed at any test point, shall be as shown in Table I.
TABLE I. PHOTOMETRIC REQUIREMENTS FOR RUNNING LAMPS
Test point coordinates | Cd | ||
Vertical | Horizontal | Min | |
10L | 100 | ||
4U | V | 400 | |
10R | 100 | ||
10L | 500 | ||
5L | 1,500 | ||
2U | V | 1,500 | |
5R | 1,500 | ||
10R | 500 | ||
10L | 500 | ||
5L | 1,500 | ||
H | V | 1,500 | |
5R | 1,500 | ||
10R | 500 | ||
10L | 300 | ||
5L | 700 | ||
2D | V | 1,500 | |
5R | 700 | ||
10R | 300 | ||
10L | 100 | ||
4D | V | 400 | |
10R | 100 |
NOTE: Maximum anywhere in the beam shall not exceed 5,000 cd.
Cal. Code Regs. Tit. 13, § 783
Note: Authority cited: Section 26103, Vehicle Code. Reference: Sections 24012 and 26103, Vehicle Code.