"3601.7 Maximum number of disconnects. The service disconnecting means shall consist of not more than six switches or six sets of circuit breakers mounted in a single enclosure or in a group of separate enclosures."
"E3901.4.2 Island and Peninsular Countertops and Work Spaces. Receptacle outlets, if installed to serve an island or peninsular countertop or work surface, shall be installed in accordance with E3901.4.3. If a receptacle outlet is not provided to serve an island or peninsular countertop or work surface, provisions shall be provided at the island or peninsula for future addition of a receptacle outlet to serve the island or peninsular countertop or work surface.
"E3901.4.3 Receptacle Outlet Location. Receptacle outlets shall be located in one or more of the following:
Receptacle outlets rendered not readily accessible by appliances fastened in place, appliance garages, sinks, or range tops as covered in the exception to Section E3901.4.1 or appliances occupying assigned spaces shall not be considered as these required outlets.
Table 4.4.4.1(1) SEER2 and HSPF2 Conversion Factors3.
Equipment Type | SEER2/SEER | EER/EER4 | HSPF/HSPF |
Ductless Systems | 1.00 | 1.00 | 0.90 |
Ducted Split System | 0.95 | 0.95 | 0.85 |
Ducted Package System | 0.95 | 0.95 | 0.84 |
Small Duct High Velocity System | 1.00 | not applicable | 0.85 |
Ducted Space-Constrained Air Conditioner | 0.97 | not applicable | not applicable |
Ducted Space-Constrained Heat Pump | not applicable | 0.85 |
"Standard reference number | Title | Referenced in code section number |
USC-FCCCHR 10th Edition Manual of Cross Connection Control | Foundation for Cross-Connection Control and Hydraulic Research University of Southern California Kaprielian Hall 300 Los Angeles CA 90089-2531 | Table P2902.3" |
Utah Code § 15A-3-206