52 Pa. Stat. § 690-340

Current through P.A. Acts 2024-18
Section 690-340 - Use of longwall insulated cable handling equipment
(a) General rule.--Energized high-voltage cables shall not be handled except when motor or shearer cables need to be trained. When cables need to be trained, high-voltage insulated gloves, mitts, hooks, tongs, slings, aprons or other personal protective equipment capable of providing protection against shock hazard shall be used to prevent direct contact with the cable.
(b) Standards, examinations, testing and replacement.--High-voltage insulated gloves, sleeves and other insulated personal protective equipment shall:
(1) have a voltage rating of at least Class 1, 7,500 volts, that meets or exceeds ASTM F496-97, Standard Specification for In-Service Care of Insulating Gloves and Sleeves (1997);
(2) be examined before each use for visible signs of damage;
(3) be removed from the underground area of the mine or destroyed when damaged or defective; and
(4) be electrically tested every six months.

52 P.S. § 690-340

2008, July 7, P.L. 654, No. 55, §340, effective in 180 days [ 1/5/2009].