N.C. Gen. Stat. § 143-143.7

Current through Session Law 2024-11
Section 143-143.7 - [Effective Until 6/30/2024] Elevator safety requirements for certain residential rental accommodations
(a) Notwithstanding the requirements of G.S. 143-139(d), any elevator in a private residence, cottage, or similar accommodation subject to taxation under G.S. 105-164.4Fshall meet the following requirements:
(1) The gap between the hoistway face of the landing door and the hoistway face of the car door shall not exceed 4 inches.
(2) Elevator doors or gates shall meet the following requirements:
a. Horizontal sliding car doors and gates shall be designed and installed to withstand a force of 75 pounds applied horizontally on an area 4 inches by 4 inches at right angles to and at any location on the car door when fully closed without permanent deformation, without exceeding a deflection of three-quarters of an inch, and without displacing the door or gate from its guides or tracks.
b. Folding car doors shall be designed and installed to withstand a force of 75 pounds applied horizontally using a 4-inch diameter sphere at any location within the folds of the door without permanent deformation, without exceeding a deflection of three-quarters of an inch, and without displacing the door from its guides or tracks.
(b) If any property subject to this section has an elevator that does not comply with subsection (a) of this section, the landlord shall prevent the operation of the elevator until the elevator has been brought into compliance by meeting the following requirements:
(1) If the elevator does not comply with subdivision (1) of subsection (a) of this section, then the landlord shall install a hoistway door space guard, a full height door baffle, or a door baffle that is at least 31.75 inches in height, each of which shall be nonremovable and shall be designed and installed to withstand a force of 75 pounds applied horizontally using a 4-inch diameter sphere at any location without permanent deformation.
(2) If the elevator door or gate does not comply with subdivision (2) of subsection (a) of this section, then the landlord shall replace it with a door or gate that complies with subdivision (2) of subsection (a) of this section.
(c) Upon installation of a door baffle, door space guard, door, or gate meeting the requirements of subsection (b) of this section, the landlord shall provide the State Fire Marshal with one of the following:
(1) A statement signed by a professional elevator installer certifying installation of the door baffle, door space guard, door, or gate meeting the requirements of subsection (b) of this section.
(2) A receipt for purchase of the door baffle, door space guard, door, or gate meeting the requirements of subsection (b) of this section, a signed statement by the landlord stating the date of installation, and photographs depicting the door baffle, door space guard, door, or gate as installed.
(d) For purposes of this section, "elevator" means a hoisting and lowering mechanism equipped with a car or platform which moves in guides, and which serves two or more floors of a building or structure.
(e) Any person who violates subsection (b) of this section by permitting the continued operation of an elevator that does not comply with subsection (a) of this section shall be guilty of a Class 2 misdemeanor.

N.C. Gen. Stat. § 143-143.7

Amended by 2023 N.C. Sess. Laws 151,s. 11.63, eff. 11/9/2023.
Added by 2022 N.C. Sess. Laws 56, s. 1, eff. 10/1/2022.
This section is set out more than once due to postponed, multiple, or conflicting amendments.