048-6 Wyo. Code R. § 6-9

Current through April 27, 2019
Section 6-9 - Equipment and Supplies

(a) There shall be appropriate equipment and supplies maintained to include, but not be limited to:

  • (1) A bed suitable for labor, birth, and recovery.
  • (2) Oxygen with flow meters and masks or equivalent.
  • (3) Mechanical suction and bulb suction.
  • (4) Cardio pulmonary resuscitation cart shall include:
    • (a) Resuscitation bags;
    • (b) Endotrachael tubes;
    • (c) Oral airways;
    • (d) Needles;
    • (e) Syringes;
    • (f) Emergency drugs;
    • (g) Laryngoscope;
    • (h) Equipment for delivering positive pressure oxygen;
    • (i) Cardiac monitor/defibrillator unit.
  • (5) Firm surfaces suitable for resuscitation.
  • (6) Emergency medications, intravenous fluids, and related supplies and equipment for both mother and newborn.
  • (7) Electronic fetal monitoring equipment.
  • (8) Transfer isolette with a temperature control and oxygen capabilities.
  • (9) Infant scale.
  • (10) A clock with a sweep second hand.
  • (11) Sterile suturing equipment and supplies.
  • (12) Adjustable lighting that is pleasant for the patient and adequate for examinations.
  • (13) Containers for soiled linen which shall be closed or covered.
  • (14) Heavy duty plastic bags shall be used for double bagging of patient wastes, as well as sanitary disposal of all wastes.
  • (15) Log book for registration of birth which shall contain at least the following:
    • (a) Mother's name;
    • (b) Patient medical record number;
    • (c) Date of delivery;
    • (d) Time of delivery;
    • (e) Mother's age;
    • (f) Gravida, Para;
    • (g) Newborn weight;
    • (h) Newborn sex;
    • (i) Gestational age;
    • (j) Transport:
      • (i) mother
      • (ii) baby
      • (iii) where
      • (iv) when
      • (v) by whom
    • (k) Death:
      • (i) neonatal
      • (ii) maternal
      • (iii) stillbirth
    • (l) Type of delivery;
    • (m) Condition of newborn at delivery/congenital anomalies;
    • (n) Delivering person;
    • (o) APGARS.
  • (16) Access to a toilet, lavatory and shower which is not used by visitors or staff.
  • (17) One (1) or more comfortable chair(s) or recliner.
  • (18) Scrub sink with elbow, knee or foot control.
  • (19) Emergency signal and/or communication system.
  • (20) Adequate ventilation and temperature control.
  • (21) Sphygmomanometer, stethoscope and fetoscope.
  • (22) Microscope for routine examinations such as urine and hematocrit.
  • (23) Any other equipment necessary to provide full scope of services and to ensure safety of mother and newborn.

048-6 Wyo. Code R. § 6-9