(a) The owner or operator must ensure that injection pressure does not exceed 90 percent of the fracture pressure of the injection zone(s) so as to ensure that the injection does not initiate new fractures or propagate existing fractures in the injection zone(s). In no case may injection pressure cause movement of injection or formation fluids in a manner that endangers a USDW, or otherwise threatens human health, safety, or the environment.
(b) Injection of the carbon dioxide stream between the outermost casing protecting USDWs and the well bore is prohibited.
(c) The owner or operator must fill the annulus between the tubing and the long string casing with a non-corrosive fluid approved by the administrator.
(d) Other than during periods of well workover (maintenance) approved by the administrator in which the sealed tubing-casing annulus is, by necessity, disassembled for maintenance or corrective procedures, the owner or operator must maintain mechanical integrity of the injection well at all times.
(e) The owner or operator must install and use continuous recording devices to monitor:
(f) The owner or operator must install and use continuous recording devices to monitor the pressure on the annulus between the tubing and the long string casing and annulus fluid volume.
(g) The owner or operator must install, test, and use alarms and automatic surface shut-off systems, or at the discretion of the administrator use down-hole shut-off systems (e.g., automatic shut-off, check valves), or other mechanical devices that provide equivalent protection, designed to alert the operator and shut-in the well when operating parameters such as injection rate, injection pressure, or other parameters approved by the administrator diverge beyond ranges and/or gradients specified in the permit.
(h) If an automatic shutdown is triggered or a loss of mechanical integrity is discovered, the owner or operator must immediately investigate and identify as expeditiously as possible the cause.
(i) If, upon such investigation, the well appears to be lacking mechanical integrity, or if monitoring required under paragraphs (e), (f), and (g) of this section otherwise indicates that the well may be lacking mechanical integrity, the owner or operator must:
020-24 Wyo. Code R. § 24-12
Amended, Eff. 7/25/2016.