(a) A public pool shall:
(b) The system of pumps, filters, disinfection facilities and other equipment shall be of adequate size to re-circulate, filter and disinfect the entire volume of pool water in the following maximum time intervals:
Pool Type | Maximum Turnover Time in Hours |
General-Use or Limited-Use pool over 2,000 square feet (185.87m²) of surface area | 6 |
Limited-Use pool less than 2,000 square feet (185.87m²) of surface area | 8 |
Wading and plunge pool | 2 |
Spa | ½ |
Flotation tank | A minimum of three (3) turnovers between users. Bather load = one (1) person per tank unit. |
; and
- (i) Overflow water shall not be less than fifty (50) percent of the total re- circulated water.
(c) A flow meter must be installed in all re-circulation systems and shall:
(d) Pressure gauges must be installed on the inlet and outlet of the filter.
(e) Spa pool recirculation systems shall be separate from adjacent swimming pools.
010-4 Wyo. Code R. § 4-13