010-4 Wyo. Code R. § 4-13

Current through April 27, 2019
Section 4-13 - Re-Circulation Systems

(a) A public pool shall:

  • (i) Have re-circulation and filtration systems with piping, pumps, filters, disinfection and other equipment to maintain the pool water quality as required by these Regulations.

(b) The system of pumps, filters, disinfection facilities and other equipment shall be of adequate size to re-circulate, filter and disinfect the entire volume of pool water in the following maximum time intervals:

Pool Type

Maximum Turnover Time in Hours

General-Use or Limited-Use pool over 2,000 square feet (185.87m²) of surface area

6

Limited-Use pool less than 2,000 square feet (185.87m²) of surface area

8

Wading and plunge pool

2

Spa

½

Flotation tank

A minimum of three (3) turnovers between

users.

Bather load = one (1) person per tank

unit.

; and

  • (i) Overflow water shall not be less than fifty (50) percent of the total re- circulated water.

(c) A flow meter must be installed in all re-circulation systems and shall:

  • (i) Measure the flow in gallons per minute;
  • (ii) Be mounted in accordance with the manufacturer's recommendations; and
  • (iii) Be easily accessible and easy to read.

(d) Pressure gauges must be installed on the inlet and outlet of the filter.

(e) Spa pool recirculation systems shall be separate from adjacent swimming pools.

010-4 Wyo. Code R. § 4-13