010-3 Wyo. Code R. § 3-23

Current through April 27, 2019
Section 3-23 - Air Blower and Air Induction Systems; Entry Devices

(a) This section pertains to all devices and systems which induce or allow air to enter the spa either by means of a power pump or passive design.

  • (i) Air intake sources shall not:
    • (A) Induce water external to the spa unit; and
    • (B) Induce dirt or contaminants into the spa.
  • (ii) An air blower installed within an enclosure or indoors shall:
    • (A) Be provided with adequate ventilation;
    • (B) Be installed in accordance with any federal, state or local codes;
    • (C) Be installed according to the manufacturer's recommendations; and
    • (D) Be accessible for inspection and service.

(b) Integral air passages shall be pressure tested at the time of manufacture to provide structural integrity to a value of one and one-half (1½) times the intended working pressure.

(c) An air induction system shall totally prevent water back-up that could cause electrical shock hazards.

(d) A hydrotherapy pump and air blower in a spa pool shall be connected to a maximum fifteen (15) minute time switch located no closer than ten (10) feet (3m) from the spa water's edge.

(e) Air blower and air induction systems must be separate from the recirculation system.

010-3 Wyo. Code R. § 3-23