Meter Size (inches) | Minimum Test Flow (g.p.m.) | Normal test flow limits (g.p.m.) |
5/8 | 1/4 | 1-20 |
3/4 | 1/2 | 2-30 |
1 | 3/4 | 3-50 |
1 1/2 | 1 1/2 | 5-100 |
2 | 2 | 8-160 |
Compound Meters | ||
2 | 1/2 | 2-160 |
3 | 1 | 4-320 |
4 | 1 1/2 | 6-500 |
6 | 3 | 10-1,000 |
8 | 4 | 16-1,600 |
10 | 8 | 32-2,300 |
12 | 14 | 32-3,100 |
Turbine Meters* | ||
2 | 10 | 16-160 |
3 | 15 | 24-350 |
4 | 20 | 40-600 |
6 | 30 | 80-1400 |
8 | 50 | 144-2,500 |
10 | 75 | 224-3,800 |
12 | 100 | 320-5,800 |
16 | 150 | 400-11,500 |
Note: See AWWA Standards C-700 (Positive Displacement Meters), C-702 (Compound Meters), and C-701 (Turbine Meters).
Note: * See s. PSC 185.61(1).
Note: It is the intent of the commission that new meters have an accuracy limits percent between 95 and 101.5.
Summary of Test Conditions and Accuracy Requirements for Positive Displacement Meters
Maximum Rate | Intermediate Rate | Minimum Rate | |||||||||||
Size in. | Rate of Flow | Test Quantity | Accuracy Limits | Rate of Flow | Test Quantity | Accuracy Limits | Rate of Flow | Test Quantity* | Accuracy Limits Percent | ||||
gpm | Gal. | Cu. Ft. | Percent | gpm | Gal. | Cu. Ft. | Percent | gpm | Gal. | Cu. Ft. | New Meters | Repaired Meters | |
5/8 | 15 | 100 | 10 | 98.5-101.5 | 2 | 10 | 1 | 98.5-101.5 | 1/4 | 10 | 1 | 95-101.5 | 90-101.5 |
3/4 | 25 | 100 | 10 | 98.5-101.5 | 3 | 10 | 1 | 98.5-101.5 | 1/2 | 10 | 1 | 95-101.5 | 90-101.5 |
1 | 40 | 100 | 10 | 98.5-101.5 | 4 | 10 | 1 | 98.5-101.5 | 3/4 | 10 | 1 | 95-101.5 | 90-101.5 |
11/2 | 80 | 1.000 | 100 | 98.5-101.5 | 8 | 100 | 10 | 98.5-101.5 | 11/2 | 100 | 10 | 95-101.5 | 90-101.5 |
2 | 120 | 1.000 | 100 | 98.5-101.5 | 15 | 100 | 10 | 98.5-101.5 | 2 | 100 | 10 | 95-101.5 | 90-101.5 |
* Section PSC 185.73(3) provides that at this flow rate the test quantity may be reduced to that equivalent to one-half revolution of the test dial. For the typical 5/8-inch meter the minimum test quantity would, therefore, be 5 gal. or 1/2 cu. ft.