Note: Per s. SPS 321.22(1), sill plates are not required on foundation walls of poured concrete or on masonry walls with mortar- or grout-filled cores or on masonry walls with a solid block top course.
Note: The floor-framing elements required in this section are intended to provide lateral support to the top of the foundation wall. See s. SPS 321.22(9) for further requirements relating to floor framing, including for bridging of floor framing to provide restraint against rotation or lateral displacement of the floor framing.
Table 321.18-A
SOIL LATERAL LOAD
Description of Backfill Materiale | Unified Soil Classification | Design Lateral Soil Loada PSF per Foot of Depth |
Well graded, clean gravels; gravel-sand mixes | GW | 30c |
Poorly graded clean gravels; gravel-sand mixes | GP | 30c |
Silty gravels, poorly graded gravel-sand mixes | GM | 40c |
Clayey gravels, poorly graded gravel-and-clay mixes | GC | 45c |
Well-graded, clean sands; gravelly sand mixes | SW | 30c |
Poorly graded clean sands; sand-gravel mixes | SP | 30c |
Silty sands, poorly graded sand-silt mixes | SM | 45c |
Sand-silt clay mix with plastic fines | SM-SC | 45d |
Clayey sands, poorly graded sand-clay mixes | SC | 60d |
Inorganic silts and clayey silts | ML | 45d |
Mixture of inorganic silt and clay | ML-CL | 60d |
Inorganic clays of low to medium plasticity | CL | 60d |
Organic silts and silt clays, low plasticity | OL | b |
Inorganic clayey silts, elastic silts | MH | 60d |
Inorganic clays of high plasticity | CH | b |
Organic clays and silty clays | OH | b |
aDesign lateral soil loads are given for moist conditions for the specified soils at their optimum densities. Actual field conditions shall govern. Submerged or saturated soil pressures shall include the weight of the buoyant soil plus the hydrostatic loads.
bUnsuitable as backfill material.
cFor relatively rigid walls, as when braced by floors, the design lateral soil load shall be increased for sand and gravel type soils to 60 psf per foot of depth. Basement walls extending not more than 8 feet below grade and supporting flexible floor systems are not considered relatively rigid walls.
dFor relatively rigid walls, as when braced by floors, the design lateral load shall be increased for silt and clay type soils to 100 psf per foot of depth. Basement walls extending not more than 8 feet below grade and supporting flexible floor systems are not considered relatively rigid walls.
eSoil classes are in accordance with the Unified Soil Classification System, ASTM D2487, and design lateral loads are for moist soil conditions without hydrostatic pressure.
Note: See s. SPS 321.15(1) (c) for trench footing requirements.
Table 321.18-B
CONCRETE WALL THICKNESSES
Type of Concrete | Nominal Thickness (inches) | Maximum Height of Unbalanced Fill1 for Material of Wall Being Supported (Wood frame - feet) |
3000 psi | 8 | 8 |
Unreinforced concrete | 10 | 9 |
122 | 10 | |
14 | 11.5 |
1Unbalanced fill is the difference in elevation between the outside grade and the basement floor.
2The maximum height of unbalanced fill for a 12-inch thick plain concrete wall may be increased to 12 feet provided the wall is constructed of concrete with a minimum compressive value of 6,000 psi at 28 days.
Note: The ASTM C887 standard is entitled, "Standard Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar."
Table 321.18-C
PLAIN MASONRY FOUNDATION WALLSd
Maximum Wall Height (ft-in) | Depth of unbalanced backfill height (ft) | Minimum nominal wall thickness (inches) | ||
Soil classes and lateral soil loada (psf per foot below exterior grade | ||||
GW, GP, SW and SP soils 30 | GM, GC, SM, SM-SC and ML soils 45 | SC, MH, ML-CL and inorganic CL soils 60 | ||
7-8 | 4 (or less) | 8 | 8 | 8 |
6 | 10 | 12 | 10 (solidb) | |
7 | 12 | 10 (solidb) | 12 (solidb) | |
8-4 | 4 (or less) | 8 | 8 | 8 |
5 | 8 | 10 | 12 | |
6 | 10 | 12 | 12 (solidb) | |
7 | 12 | 12 (solidb) | Note c | |
8 | 10 (solidb) | 12 (solidb) | Note c | |
9-1 | 4 (or less) | 8 | 8 | 8 |
5 | 8 | 10 | 12 | |
6 | 12 | 12 | 12 (solidb) | |
7 | 12 (solidb) | 12 (solidb) | Note c | |
8 | 12 (solidb) | Note c | Note c | |
9 | Note c | Note c | Note c |
a For design lateral soils, see s. SPS 321.18(1) (e). Soil classes are in accordance with the Unified Soil Classification System and design lateral soil loads are for moist soil conditions without hydrostatic pressure.
b Solid grouted hollow units.
c An analysis in compliance with ACI 530 or reinforcement in accordance with Table 321.18-D, 321.18-E or 321.18-F is required.
d Mortar shall be Type M or S and masonry shall be laid in running bond.
Table 321.18-Db,c,d
8, 10 OR 12 IN. REINFORCED MASONRY FOUNDATION WALLS WHERE d >= 5 in.e
Maximum Wall Height (ft-in) | Height of unbalanced backfill (ft) | Vertical reinforcement | ||
Soil classes and lateral soil loada (psf per foot below exterior grade) | ||||
GW, GP, SW and SP soils 30 | GM, GC, SM, SM-SC and ML soils 45 | SC, MH, ML-CL and inorganic CL soils 60 | ||
7-8 | 4 (or less) | #4 at 48" o.c. | #4 at 48" o.c. | #4 at 48" o.c. |
5 | #4 at 48" o.c. | #4 at 48" o.c. | #4 at 40" o.c. | |
6 | #4 at 48" o.c. | #5 at 48" o.c. | #5 at 40" o.c. | |
7 | #4 at 40" o.c. | #5 at 40" o.c. | #6 at 48" o.c. | |
8-4 | 4 (or less) | #4 at 48" o.c. | #4 at 48" o.c. | #4 at 48" o.c. |
5 | #4 at 48" o.c. | #4 at 48" o.c. | #4 at 40" o.c. | |
6 | #4 at 48" o.c. | #5 at 48" o.c. | #5 at 40" o.c. | |
7 | #5 at 48" o.c. | #6 at 48" o.c. | #6 at 40" o.c. | |
8 | #5 at 40" o.c. | #6 at 40" o.c. | #7 at 40" o.c. | |
9-1 | 4 (or less) | #4 at 48" o.c. | #4 at 48" o.c. | #4 at 48" o.c. |
5 | #4 at 48" o.c. | #4 at 48" o.c. | #5 at 48" o.c. | |
6 | #4 at 48" o.c. | #5 at 48" o.c. | #6 at 48" o.c. | |
7 | #5 at 48" o.c. | #6 at 48" o.c. | #7 at 48" o.c. | |
8 | #5 at 40" o.c. | #7 at 48" o.c. | #8 at 48" o.c. | |
9 | #6 at 40" o.c. | #8 at 48" o.c. | #8 at 32" o.c. |
a For design lateral soil loads, see s. SPS 321.18(1) (e). Soil classes are in accordance with the Unified Soil Classification System and design lateral soil loads are for moist soil conditions without hydrostatic pressure.
b Provisions for this table are based on construction requirements specified in s. SPS 321.18(3) (b).
c For alternative reinforcement, see s. SPS 321.18(3) (b).
d Mortar shall be Type M or S and masonry shall be laid in running bond.
e The specified location of the reinforcement shall equal or exceed the effective depth distance, d, measured from the face of the soil side of the wall to the center of vertical reinforcement.
Table 321.18-Eb,c,d
10 OR 12 IN. REINFORCED MASONRY FOUNDATION WALLS WHERE d >= 6.75 in.e
Maximum Wall Height (ft-in) | Height of unbalanced backfill (ft) | Vertical reinforcement | ||
Soil classes and lateral soil loada (psf per foot below exterior grade) | ||||
GW, GP, SW and SP soils 30 | GM, GC, SM, SM-SC and ML soils 45 | SC, MH, ML-CL and inorganic CL soils 60 | ||
7-8 | 4 (or less) | #4 at 56" o.c. | #4 at 56" o.c. | #4 at 56" o.c. |
5 | #4 at 56" o.c. | #4 at 56" o.c. | #4 at 56" o.c. | |
6 | #4 at 56" o.c. | #4 at 48" o.c. | #4 at 40" o.c. | |
7 | #4 at 56" o.c. | #5 at 56" o.c. | #5 at 40" o.c. | |
8-4 | 4 (or less) | #4 at 56" o.c. | #4 at 56" o.c. | #4 at 56" o.c. |
5 | #4 at 56" o.c. | #4 at 56" o.c. | #4 at 48" o.c. | |
6 | #4 at 56" o.c. | #4 at 48" o.c. | #5 at 56" o.c. | |
7 | #4 at 48" o.c. | #4 at 32" o.c. | #6 at 56" o.c. | |
8 | #5 at 56" o.c. | #5 at 40" o.c. | #7 at 56" o.c. | |
9-1 | 4 (or less) | #4 at 56" o.c. | #4 at 56" o.c. | #4 at 56" o.c. |
5 | #4 at 56" o.c. | #4 at 56" o.c. | #4 at 48" o.c. | |
6 | #4 at 56" o.c. | #4 at 40" o.c. | #4 at 32" o.c. | |
7 | #4 at 40" o.c. | #5 at 48" o.c. | #6 at 48" o.c. | |
8 | #4 at 32" o.c. | #6 at 48" o.c. | #4 at 16" o.c. | |
9 | #5 at 40" o.c. | #6 at 40" o.c. | #7 at 40" o.c. |
a For design lateral soil loads, see s. SPS 321.18(1) (e). Soil classes are in accordance with the Unified Soil Classification System and design lateral soil loads are for moist soil conditions without hydrostatic pressure.
b Provisions for this table are based on construction requirements specified in s. SPS 321.18(3) (b).
c For alternative reinforcement, see s. SPS 321.18(3) (b).
d Mortar shall be Type M or S and masonry shall be laid in running bond.
e The specified location of the reinforcement shall equal or exceed the effective depth distance, d, measured from the face of the soil side of the wall to the center of vertical reinforcement.
Table 321.18-Fb,c,d
12 IN. REINFORCED MASONRY FOUNDATION WALLS WHERE d >= 8.75 in.e
Maximum Wall Height (ft-in) | Height of unbalanced backfill (ft) | Vertical reinforcement | ||
Soil classes and lateral soil loada (psf per foot below exterior grade) | ||||
GW, GP, SW and SP soils 30 | GM, GC, SM, SM-SC and ML soils 45 | SC, MH, ML-CL and inorganic CL soils 60 | ||
7-8 | 4 (or less) | #4 at 72" o.c. | #4 at 72" o.c. | #4 at 72" o.c. |
5 | #4 at 72" o.c. | #4 at 72" o.c. | #4 at 72" o.c. | |
6 | #4 at 72" o.c. | #4 at 64" o.c. | #4 at 48" o.c. | |
7 | #4 at 72" o.c. | #4 at 48" o.c. | #5 at 56" o.c. | |
8-4 | 4 (or less) | #4 at 72" o.c. | #4 at 72" o.c. | #4 at 72" o.c. |
5 | #4 at 72" o.c. | #4 at 72" o.c. | #4 at 72" o.c. | |
6 | #4 at 72" o.c. | #4 at 56" o.c. | #5 at 72" o.c. | |
7 | #4 at 64" o.c. | #5 at 64" o.c. | #4 at 32" o.c. | |
8 | #4 at 48" o.c. | #4 at 32" o.c. | #5 at 40" o.c. | |
9-1 | 4 (or less) | #4 at 72" o.c. | #4 at 72" o.c. | #4 at 72" o.c. |
5 | #4 at 72" o.c. | #4 at 72" o.c. | #4 at 64" o.c. | |
6 | #4 at 72" o.c. | #4 at 56" o.c. | #5 at 64" o.c. | |
7 | #4 at 56" o.c. | #4 at 40" o.c. | #6 at 64" o.c. | |
8 | #4 at 40" o.c. | #6 at 64" o.c. | #6 at 48" o.c. | |
9 | #5 at 56" o.c. | #7 at 72" o.c. | #6 at 40" o.c. |
aFor design lateral soil loads, see s. SPS 321.18(1) (e). Soil classes are in accordance with the Unified Soil Classification System and design lateral soil loads are for moist soil conditions without hydrostatic pressure.
b Provisions for this table are based on construction requirements specified in s. SPS 321.18(3) (b).
c For alternative reinforcement, see s. SPS 321.18(3) (b).
d Mortar shall be Type M or S and masonry shall be laid in running bond.
e The specified location of the reinforcement shall equal or exceed the effective depth distance, d, measured from the face of the soil side of the wall to the center of vertical reinforcement.
Wis. Admin. Code Department of Safety and Professional Services SPS 321.18
The department will accept Permanent Wood Foundations Design and Construction Guide published by the Southern Forest Products Association through the Southern Pine Council, as complying with this standard. The Design and Construction Guide requires a 3.5 inch thick floor slab if a poured concrete floor slab is used.