Table 384.30-1
ABOVE GROUND DRAIN AND VENT PIPE AND TUBING
Material | Standard |
Acrylonitrile butadiene styrene (ABS) | ASTM D1527; ASTM D2661 |
Acrylonitrile butadiene styrene (ABS) coextruded | ASTM F628 |
Brass | ASTM B43 |
Cast iron | ASTM A74; ASTM A888; CISPI 301 |
Chlorinated Poly Vinyl Chloride (CPVC) | ASTM F441/F441M; ASTM F442/F442M; ASTM F2618; ASTM D2846/D2846M |
Copper | ASTM B42; ASTM B88; ASTM B306 |
Ductile iron | AWWA C115/A21.15; AWWA C151/A21.51 |
Galvanized steel | ASTM A53 |
Polyethylene (PE) | ASTM F1901 |
Polypropylene | ASTM F1412 |
Polyvinyl chloride (PVC) | ASTM D2665; ASTM D1785; ASTM F891b; AWWA C900 |
Polyvinylidene fluoride (PVDF) | ASTM F1673 |
Stainless steel (316L) | ASME A112.3.1; ASME B36.19 / B36.19M; ASTM A269/A269M; ASTM A312/A312M; ASTM A450/A450M; ASTM A778/A778M; AWWA C220 |
Stainless steel (304) | ASME A112.3.1; ASME B36.19 / B36.19M; ASTM A269/A269M; ASTM A312/A312M; ASTM A450/A450M; ASTM A778/A778M; AWWA C220 |
Synthetic rubber hosea | AHAM DW-2-2020 |
a. The installation of synthetic rubber hose is limited in use to indirect waste piping or local waste piping from dishwashers in accordance with s. SPS 382.33 (9) (d).
b. Limited to pipe weight of schedule 40.
Table 384.30-2
UNDERGROUND DRAIN AND VENT PIPE AND TUBING
Material | Standard |
Acrylonitrile butadiene styrene (ABS) | ASTM D1527; ASTM D2661 |
Acrylonitrile butadiene styrene (ABS) coextruded | ASTM F628 |
Brass | ASTM B43 |
Cast iron | ASTM A74; ASTM A888; CISPI 301 |
Chlorinated Poly Vinyl Chloride (CPVC)d | ASTM D2846/D2846M; ASTM F441/F441M; ASTM F442/F442M; ASTM F2618 |
Coppera | ASTM B42; ASTM B88 |
Ductile iron | AWWA C115/A21.15; AWWA C151/A21.51 |
Polyvinyl chloride (PVC) | ASTM D1785; ASTM D2665; ASTM D3034b; ASTM F891c; AWWA C900 |
Stainless steel d | ASME A112.3.1; ASME B36.19 / B36.19M; ASTM A269/A269M; ASTM A312/A312M; ASTM A450/A450M; ASTM A778/A778M; AWWA C220 |
a. Copper tubing, type M, may not be installed underground.
b. Limited to pipe with a SDR of 26 or less.
c. Limited to pipe weight of schedule 40.
d. Type 304 may not be installed underground.
Table 384.30-3
SANITARY BUILDING SEWER PIPE AND TUBING
Material | Standard |
Acrylonitrile butadiene styrene (ABS)a | ASTMD1527; ASTM D2661; ASTM D2751 |
Acrylonitrile butadiene styrene (ABS) coextruded | ASTM F628 |
Acrylonitrile butadiene styrene (ABS) compositea | ASTM D2680 |
Brass | ASTM B43 |
Cast iron | ASTM A74; ASTM A888; CISPI 301 |
Chlorinated polyvinyl chloride (CPVC)c | ASTM F441/F441M; ASTM F442/F442M; ASTM F2618; ASTM D2846 |
Concrete | ASTM C14; ASTM C76 |
Copperb | ASTM B42; ASTM B88 |
Ductile iron | AWWA C115/A21.15; AWWA C151/A21.51 |
Polyethylene (PE) | ASTM F714; ASTM F894; ASTM F2763/F2763M |
Polyvinyl chloride (PVC)a | ASTM D1785; ASTM D2665; ASTM D2729; ASTM D3034; ASTM F794; ASTM F891; ANSI/AWWA C900 |
Polypropylene (PP) | ASTM F1412; ASTM F2764/F2764M |
PVC Corrugated Sewer Pipe With a Smooth Interior and Fittingsa | ASTM F949 |
PVC Large-Diameter Plastic Gravity Sewer Pipe and Fittingsa | ASTM F679 |
PVC Profile Gravity Sewer Pipe and Fittings Based on Controlled Inside Diametera | ASTM F794 |
Type PS-46 and Type PS-115 PVC Plastic Gravity Flow Sewer Pipe and Fittingsa | ASTM F789 |
Stainless steel (316L) | ASME A112.3.1; ASME B36.19 / B36.19M; ASTM A269/A269M; ASTM A312/A312M; ASTM A450/A450M; ASTM A778/A778M; AWWA C220 |
Vitrified clay (extra strength) | ASTM C700 |
a. Thermoplastic sewer pipe shall be installed in accordance with ASTM D2321.
b. Copper tubing, type M, may not be installed underground.
Table 384.30-4
PERFORATED EFFLUENT DISTRIBUTION PIPING FOR NONPRESSURIZED SOIL ABSORPTION SYSTEMS
Material | Standard |
Acrylonitrile butadiene styrene (ABS) | ASTM D1527; ASTM D2661; ASTM D2751 |
Acrylonitrile butadiene styrene (ABS) coextruded | ASTM F628 |
Acrylonitrile butadiene styrene (ABS) composite | ASTM D2680 |
Brass | ASTM B43 |
Cast iron | ASTM A74; ASTM A888; CISPI 301 |
Chlorinated polyvinyl chloride (CPVC) | ASTM F2618 |
Ductile iron | AWWA C115/A21.51; AWWA C151/A21.15 |
Polyethylene (PE)a | ASTM F667/F667M; ASTM F810 |
Polypropylene (PP) | ASTM F1412; ASTM F2764/F2764M |
Polyvinyl chloride (PVC)a | ASTM D2729; ASTM D3034; ASTM F891 |
Vitrified clay (extra strength) | ASTM C4; ASTM C700 |
a. The pipe shall have 2 rows, and only 2 rows, of perforations parallel to the axis of the pipe and 120° + 5° apart. The perforations shall be at the nominal 4 and 8 o'clock positions when the pipe is installed.
Table 384.30-5
PRESSURIZED DRAIN PIPE AND TUBING AND SERVICE SUCTION LINES
Material | Standard |
Acrylonitrile butadiene styrene (ABS)a | ASTM D1527; ASTM D2661 |
Acrylonitrile butadiene styrene (ABS)a coextruded | ASTM F628 |
Brass | ASTM B43 |
Chlorinated Poly (Vinyl Chloride) (CPVC)a | ASTM D2846; ASTM F441/F441M; ASTM F442/F442M |
Concrete | ASTM C14; ASTM C76 |
Copperb | ASTM B42; ASTM B88; ASTM B306 |
Ductile iron | AWWA C115/A21.15; AWWA C151/A21.51 |
Galvanized steel | ASTM A53 |
Polyethylene Pressure Pipe and Fitting, 4 in. through 63 in., for Water Distribution | AWWA C906 |
Polyethylene (PE) Pressure Pipe and Tubing, 1/2 in. through 3 in. | AWWA C901 |
Polyvinyl chloride (PVC)a | ASTM D1785; ASTM D2241; ASTM D2665; AWWA C900 |
Stainless Steel (316L) | ASME A112.3.1; ANSI B36.19M; ASTM A269; A312/A312M; ASTM A450; ASTM A778/778M; AWWA C220 |
a. Thermoplastic sewer pipe shall be installed in accordance with ASTM D2774.
b. Copper tubing, type M, may not be installed underground
Note: See s. SPS 382.36 (10) and (11) for additional roof drain requirements.
Table 384.30-6
STORM BUILDING SEWER PIPE AND TUBING
Material | Standard |
Acrylonitrile butadiene styrene (ABS)a | ASTM D1527; ASTM D2661; ASTM D2751 |
Acrylonitrile butadiene styrene (ABS)a coextruded | ASTM F628 |
Acrylonitrile butadiene styrene (ABS) compositea | ASTM D2680 |
Brass | ASTM B43 |
Cast iron | ASTM A74; ASTM A888; CISPI 301 |
Chlorinated polyvinyl chloride (CPVC) | ASTM F2618 |
Concrete, circular | ASTM C14; ASTM C76 |
Concrete, elliptical | ASTM C507/C507M |
Copperb | ASTM B42; ASTM B88 |
Ductile iron | AWWA C115/A21.15; AWWA C151/A21.15 |
Polyethylene (PE) | ASTM F714; ASTM F2763/F2763M |
Polypropylene (PP) | ASTM F1412; ASTM F2764/F2764M; ASTM F2881/F2881M |
Polyvinyl chloride (PVC)a | ASTM D1785; ASTM D2665; ASTM D2729; ASTM D3034; ASTM F891 |
PVC Corrugated Sewer Pipe With a Smooth Interior and Fittings | ASTM F949 |
PVC Large-Diameter Plastic Gravity Sewer Pipe and Fittings | ASTM F679 |
PVC Profile Gravity Sewer Pipe and Fittings Based on Controlled Inside Diameter | ASTM F794 |
Stainless steel (316L) | ASME A112.3.1; ASME B36.19 / B36.19M; ASTM A269/A269M; ASTM A312/A312M; ASTM A450/A450M; ASTM A778/A778M; AWWA C220 |
Type PS-46 and Type PS-115 PVC Plastic Gravity Flow Sewer Pipe and Fittings | ASTM F789 |
Vitrified clay | ASTM C700 |
a. Thermoplastic sewer pipe shall be installed in accordance with ASTM D2774.
b. Copper tubing, type M, may not be installed underground.
Note: For a listing of nationally recognized agencies acceptable to the department, see ch. SPS 384 Appendix A-384.11.
Note: Portions of a water supply system that supply water to a water-based fire protection system are to also conform to chs. SPS 361 to 365.
Note: See ch. SPS 384 Appendix for further explanation.
Table 384.30-7
PIPE AND TUBING FOR WATER SERVICES AND PRIVATE WATER MAINS
Material | Standard |
Acrylonitrile butadiene styrene (ABS)a | ASTM D1527; ASTM D2282 |
Brass | ASTM B43 |
Chlorinated Poly (Vinyl Chloride) (CPVC)a | ASTM D2846; ASTM F441/F441M; ASTM F442/F442M |
Chlorinated polyvinyl chloride composite (CPVC/Al/ CPVC) | ASTM F2855 |
Copperb,c | ASTM B42; ASTM B75; ASTM B88; ASTM B135; ASTM B251; ASTM B302; ASTM B447 |
Crosslinked Polyethylene/ Aluminum/Crosslinked Polyethylene (PEX/Al/ PEX) | CAN/CSA B137.10; ASTM F1281 |
Crosslinked polyethylene (PEX)a | ASTM F876; ASTM F877; AWWA C904 |
Ductile iron | AWWA C115/A21.15; AWWA C151/A21.51 |
Galvanized steel | ASTM A53 |
Polyethylene (PE)a | ASTM D2239; ASTM D2737; ASTM D2104; ASTM D2447; ASTM D3035; AWWA C906; AWWA C901 |
Polyethylene/Aluminum/Polyethylene | CAN/CSA B137.9 |
Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe | ASTM F1282 |
Polyethylene raised temperature (PE-RT) | ASTM F2769 |
Polyethylene raised temper-ature/al/polyethylene raised temperature (PE-RT/Al/PE-RT) | ASTM F3346 |
Polypropylene (PP-RCT) | ASTM F2389 |
Polyvinyl chloride (PVC)a | ASTM D1785; ASTM D2241; AWWA C900 |
Stainless steel (316L) | ASME B36.19/B36.19M; ASTM A269; ASTM A270; ASTM A312; ASTM A358/A358M; ASTM A450; ASTM A554; ASTM A778/A778M |
a. Plastic water service systems shall be installed in accordance with ASTM D2774.
b. Copper tubing, type M, may not be installed underground.
c. Copper pipe or tubing shall not be installed if the pH of the water to be conveyed is 6.5 or less.
d. May not be threaded.
Table 384.30-8
WATER DISTRIBUTION PIPE AND TUBING
Material | Standard |
Brass | ASTM B43 |
Cast iron | AWWA C115/A21.15 |
Chlorinated Poly (Vinyl Chloride) (CPVC)a | ASTM D2846; ASTM F441/441c; ASTM F442/442Md |
Chlorinated polyvinyl chloride composite (CPVC/Al/ CPVC) | ASTM F2855 |
Copperb,e | ASTM B42; ASTM B75; ASTM B88; ASTM B135; ASTM B251; ASTM B302; ASTM B447 |
Crosslinked Polyethylene/ Aluminum/Crosslinked Polyethylene (PEX/Al/ PEX) | CAN/CSA B137.10, ASTM F1281 |
Crosslinked polyethylene (PEX)a | ASTM F876; ASTM F877; AWWA C904 |
Ductile iron | AWWA C115/A21.15; AWWA C151//A21.51 |
Galvanized steel | ASTM A53 |
Polyethylene/Aluminum/ Polyethylene | CAN/CSA B137.9 |
Polyethylene/Aluminum/ Polyethylene (PE-AL-PE) Composite Pressure Pipe | ASTM F1282 |
Stainless Steel (316L) | ASME B36.19M; ASTM A269; ASTM A270; ASTM A312; ASTM A358/A358M; ASTM A450; ASTM A554; ASTM A778/A778M |
a. Plastic pipe and tubing installed underground shall be in accordance with ASTM D2774.
b. Copper tubing, type M, may not be installed underground.
c. Use is limited to pipe 2 1/2 inches or less in diameter for sch 80 and 1 inch or less in diameter for sch 40.
d. Use is limited to pipe with a SDR 11 or less.
e. Copper pipe or tubing shall not be installed if the pH of the water to be conveyed is 6.5 or less.
f. Use is limited to cold water distribution only.
g. May not be threaded.
Note: Reduced pressure backflow preventers and reduced pressure detector fire protection backflow preventers are not permitted for cross connection control.
Note: Double check fire protection backflow preventer assemblies are not permitted for cross connection control.
Table 384.30-11
Pipe And Tubing For Water Distribution Systems Downstream Of Treatment Devices Designed To Serve Fixtures, Appliances And Devices That Provide [LESS THAN EQUAL TO] 1 Gpm At Each Outlet
Material | Standard |
Copperb,c | ASTM B42; ASTM B88 |
Polyethylene (PE)a | NSF 51; NSF 61 |
Polypropylene (PP)a | NSF 51; NSF 61 |
Polyvinylidene fluoride (PVDF)a | NSF 51; NSF 61 |
Polyvinyl chloride (PVC)a | NSF 51; NSF 61 |
a These materials are approved for cold water use only.
b Copper tubing, Type M, shall not be installed underground.
c Copper pipe or tubing shall not be installed if the pH of the water to be conveyed is 6.5 or less.
Table 384.30-12
GEOTEXTILE FABRICS
Property | Test Method | Minimum Average Roll Value |
Grab Tensile, lbs | ASTM D4632 | 35 lbs, minimum |
Grab Elongation, % | ASTM D4632 | 50%, minimum |
Puncture, lbs | ASTM D4833 | 10 lbs, minimum |
Trapezoidal tear, lbs | ASTM D4533 | 11 lbs, minimum |
AOS, US Sieve # | ASTM D4751 | 20 US sieve #, minimum |
AOS, US Sieve # | ASTM D4751 | 70 US sieve #, maximum |
Note: Stone that can scratch a copper penny without leaving any residual stone material on the penny has a hardness value of at least 3 on Moh's Scale of Hardness.
Wis. Admin. Code Department of Safety and Professional Services SPS 384.30