Appurtenances, devices, fixtures, materials and methods shall conform to the referenced standard in Table 384.11. Appurtenances, devices, fixtures, materials, and methods shall be listed by a nationally recognized, ANSI accredited, third party agency acceptable to the department. Appurtenances, devices, fixtures, materials, and methods that do not conform to the listed standards may achieve code compliance via Alternate or Experimental approvals in accordance with s. SPS 384.50.
Wis. Admin. Code Department of Safety and Professional Services SPS 384.11
See s. SPS 381.20 for complete standard designations and ch. SPS 384 Appendix for acceptable listing agencies.
Table 384.11
Appurtenances, Devices, Fixtures, Materials and Methods
Appurtenance, Device, Fixture, Material or Method | Referenced Standard(s)a |
Appurtenances, Devices and Fixtures | |
1. Automatic Clothes Washers, Residential | ASSE 1007 |
2. Bathtubs, Enameled Cast Iron | ASME A112.19.1/CSA B45.2 |
3. Bathtubs, Plastic | CSA B45.5/IAPMO Z124 |
4. Bathtubs, Porcelain Enameled Formed Steel | ASME A112.19.4M |
5. Bidets, Vitreous and Non-Vitreous China | ASME A112.19.2/CSA B45.1 |
6. Dishwashing Machines, Household Electric | AHAM DW-2 |
7. Dishwashing Machines, Commercial | ASSE 1004 |
8. Dishwashing Machines, Residential | ASSE 1006 |
9. Drinking Fountains | ASME A112.19.2/CSA B45.1 |
10. Faucets and Showerheads | ASME A112.18.1/CSA B125.1 |
11. Food Waste Grinders, Residential | ASSE 1008 |
12. Ice Making Equipment, Automatic | NSF 12 |
13. Lavatories, Enameled Cast iron | ASME A112.19.1/CSA B45.2 |
14. Lavatories, Integral to Cultured Marble Vanity Tops | CSA B45.5-17/IAPMO Z124 |
15. Lavatories, Plastic | CSA B45.5-17/IAPMO Z124 |
16. Lavatories, Porcelain | ASME A112.19.4M |
17. Lavatories, Stainless Steel | ASME A112.19.3/CSA B45.4 |
18. Lavatories, Vitreous China | ASME A112.19.2/CSA B45.1 |
19. Macerating Toilet Systems and Waste Pumping Systems for Plumbing Fixtures | ASME A112.3.4/CSA B45.9 |
20. Personal Hygiene Devices for Water Closets (Bidet Seats) | ASME A112.4.2/CSA B45.16 |
21. Showers, Prefabricated Plastic | CSA B45.5/IAPMO Z124 |
22. Sinks, Enameled Cast Iron | ASME A112.19.1/CSA B45.2 |
23. Sinks, Plastic | CSA B45.5/IAPMO Z124 |
24. Sinks, Porcelain Enameled Formed Steel | ASME A112.19.4M |
25. Sinks, Stainless Steel | ASME A112.19.3/CSA B45.4 |
26. Sinks, Vitreous China | ASME A112.19.2/CSA B45.1 |
27. Supports, Floor Affixed for Off-the-Floor Plumbing Fixtures for Public Use | ASME A112.6.1M |
28. Supports, Framing Affixed, Off-the-Floor Plumbing Fixtures | ASME A112.6.2 |
29. Urinals, Plastic | CSA B45.5/IAPMO Z124 |
30. Urinals, Vitreous China | ASME A112.19.2/CSA B45.1 |
31. Water Closets, Plastic | CSA B45.5/IAPMO Z124 |
32. Water Closets, Vitreous China | ASME A112.19.2/CSA B45.1 |
Connections, Fittings, Joints and Valves | |
33. Connectors, Flexible | A112.18.6/CSA B125.6 |
34. Connectors, Resilient, Between Reinforced Concrete Manhole Structures and Corrugated Dual-and Triple-Wall PE and PP Pipes, Standard Specification for | ASTM F2510/F2510M |
35. Connectors, Resilient, Between Reinforced Concrete Manhole Structures, Pipes and Laterals, Standard Specification for | ASTM C923/C923M |
36. Connectors, Resilient, Between Reinforced Concrete On-Site Wastewater Tanks and Pipes, Standard Specification for | ASTM C1644 |
37. Connectors, Resilient, Storm Drain Resilient Connectors Between Reinforced Concrete Storm Sewer Structures, Pipes and Laterals, Standard Specification for | ASTM C1478 |
38. Fittings, Acrylonitrile Butadiene Styrene (ABS) | ASTM D2468, ASTM D3311, ASTM F409 |
39. Fittings, Appurtenances or Valves for use in CPVC or CPVC Systems, Specially Engineered | ASTM F1970 |
40. Fittings, Cast Bronze | ASME B16.15, ASME B16.24 |
41. Fittings, Cast Copper Alloy | ASME B16.18, ASME B16.23, ASME B16.26 |
42. Fittings, Cast Iron | ASME B16.1, ASME B16.4, ASME B16.12, ASME B16.45 |
43. Fittings, Chlorinated Polyvinyl Chloride (CPVC) | ASTM F437, ASTM F438, ASTM F439 |
44. Fittings, Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing | ASTM F1960 |
45. Fittings, Cold-Expansion with Metal Compression-Sleeves for Crosslinked Polyethylene (PEX) Pipe and SDR9 Polyethylene of Raised Temperature (PE-RT) Pipe | ASTM F2080 |
46. Fittings, Copper | ASME B16.22, ASME B16.29 |
47. Fittings, Crosslinked Polyethylene (PEX) | ASTM F1807 |
48. Fittings, Ductile Iron and Gray Iron | AWWA C110, AWWA C153, ASME B16.42 |
49. Fittings, Gray Iron Pipe Flanges and Flanged Fitting Classes 25, 125 and 250 | ASME B16.1 |
50. Fittings, Gray Iron Threaded Fitting Classes 125 and 250 | ASME B16.4 |
51. Fittings, Malleable Ironb | ASME B16.3 |
52. Fittings, Metric- and Inch-Sized Fittings for PEX Pipe | ASTM F2829/F2829M |
53. Fittings, Polyethylene (PE) | ASTM D2609, ASTM D2683, ASTM D3261 |
54. Fittings, Polyvinyl Chloride (PVC) | ASTM D2464, ASTM D2466, ASTM D2467, ASTM D3311, ASTM F409, ASTM F1336, ASTM F1866 |
55. Fittings, Polyvinyl Chloride (PVC) Gasketed Sewer | ASTM F1336 |
56. Fittings, Push-Fitc,d | ASSE 1061 |
57. Fittings, Push-Fit PEX Mechanical Fittings for PEX Tubing | ASTM F2854 |
58. Fittings, Stainless Steel | ASTM A403/A403M, ASTM A774/A774M |
59. Fittings, Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and PEX Pipe and Tubing | ASTM F1055-16a |
60. Fittings, Steele | ASME B16.5, ASME B16.9, ASME B16.11, ASME B16.28 |
61. Fittings, Styrene-Rubber (SR) | ASTM D2852 |
62. Food Waste Grinders, Commercial | ASSE 1009 |
63. Gaskets, Rubber for Cast Iron Soil Pipe and Fittings | ASTM C564, CISPI 301, FM 1680 |
64. Insert Fittings, Metal, for PE-AL-PE and Crosslinked PEX-AL-PEX Composite Pressure Pipe, Standard Specification for | ASTM D1974 |
65. Insert Fittings, Metal, Utilizing a Copper Crimp Ring for SDR9 PEX and SDR9 PEX-AL-PEX Tubing, Standard Specification for | ASTM F2434 |
66. Insert Fittings, Metal Press with Factory Assembled Stainless Steel Press Sleeve for SDR9 Crosslinked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE- RT) Tubing | ASTM F3347 |
67. Insert Fittings, Plastic, for SDR9 PEX and PE-RT Tubing | ASTM F2735 |
68. Insert Fittings, Plastic Press with Factory Assembled Stainless Steel Press Sleeve for SDR9 Crosslinked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE- RT) Tubing | ASTM F3348 |
69. Insert Fittings, Plastic Utilizing a Copper Crimp Ring, or Alternate Stainless Steel Clamps for SDR9 Crosslinked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing | ASTM F2159 |
70. Insert Fittings, Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) to Metal Insert and Plastic Insert Fittings | ASTM F2098 |
71. Joints, for Concrete Gravity Flow Sewer Pipe Using Rubber Gaskets, Standard Specification for | ASTM C1628 |
72. Joints for Concrete Pipe and Manholes, Using Rubber Gaskets | ASTM C443/C443M |
73. Joints for Concrete Pipe, Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants | ASTM C990/C990M |
74.Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals | ASTM D3212 |
75. Joints, for Concrete Gravity Flow Sewer Pipe Using Rubber Gaskets, Standard Specification for | ASTM C1628 |
76. Joints, Plastic Pressure Pipes Using Flexible Elastomeric Seals | ASTM D3139 |
77. Joints, Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings | AWWA C111/A21.11 |
78. Joints, Threadedf | ASME B1.20.1 |
79. Primers for Use in Solvent Cement Joints of PVC Plastic Pipe and Fittings, Standard Specification for | ASTM F656 |
80. Solder | ASTM B32 |
81. Solvent cement, ABS | ASTM D2235 |
82. Solvent cement, CPVC | ASTM F493 |
83. Solvent cement, PVC | ASTM D2564 |
84. Solvent cements for Transition Joints Between ABS and PVC Non-Pressure Piping Components, Standard Specification for | ASTM D3138 |
85. Unions, Dielectric | ASSE 1079 |
86. Valves, Air Admittance (AAVs) | ASSE 1050, ASSE 1051 |
87. Valves, Automatic Temperature Control Mixing | ASSE 1069 |
88. Valves, Backwater | ASME A112.14.1, CSA B181.0:21 (section 5.6) |
89. Valves, Crosslinked polyethylene (PEX) Water Distribution Tubing Systems | NSF 359 |
90. Valves, Flush and spuds for water closets, urinals, and tanks | ASME A112.19.5/CSA B45.15 |
91. Valves, Flushing Devices, Pressurized for Plumbing Fixtures | ASSE 1037/ASME A112.1037/CSA B125.37 |
92. Valves, Pressure Balancing Thermostatic Control | ASSE 1016/ASME A112.1016/CSA B125.16 |
93. Valves, Relief and Automatic Shutoff Devices for Hot Water Supply Systems | ANSI Z21.22/CSA 4.4 |
94. Valves, Temperature Actuated Mixing for Hot Water Distribution Systems | ASSE 1017 |
95. Valves, Trap Primer | ASSE 1018 |
96. Valves, Trap Seal Primer - Drainage Types and Electric Design Types | ASSE 1044 |
97. Valves, Water Pressure Reducing for Potable Water Supply Systems | ASSE 1003 |
98. Water Hammer Arrestors | ASSE 1010 |
99. Water Meters | AWWA C700, AWWA C701, AWWA C702, AWWA C704, AWWA C706, AWWA C707, AWWA C708, AWWA C710 |
Cross Connection Control | |
100. Anti-siphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks | ASSE 1002/ASME A112.1002/CSA B125.12 |
101. Atmospheric Type Vacuum Breakers (AVB) | ASSE 1001, CSA B64.1.1 |
102. Backflow Preventers for Beverage Dispensing Equipment | ASSE 1022 |
103. Backflow Preventers for Hand-Held Showers | ASSE 1014, ASME A112.18.1/CSA B125.1, ASME A112.18.3 |
104. Backflow Preventers with Integral Pressure Reducing Boiler Feed Valve and Intermediate Atmospheric Vent Style for Domestic and Light Commercial Water Distribution Systemsg | ASSE 1081 |
105. Backflow Preventers with Intermediate Atmospheric Vents | ASSE 1012 |
106. Backflow Protection Devices and Systems in Plumbing Fixture Fittings | ASME A112.18.3 |
107. Chemical Dispensing Systems | ASSE 1055 |
108. Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies (DC and DCF) | ASSE 1015, CSA B64.5 |
109. Double Check Detector Fire Protection Backflow Prevention Assemblies (DCDA and DCDA-II) | ASSE 1048 |
110. Double Check Valve Backflow Preventers (DCVA) | CSA B64.5 |
111. Dual Check Backflow Preventers (DuC) | ASSE 1024, CSA B64.6 |
112. Dual Check Backflow Preventers in Freeze Resistant Type Wall Hydrants | ASSE 1053 |
113 Dual Check Valve Backflow Preventers with Atmospheric Ports (DCAP) | CSA B64.3 |
114. Dual Check Valve Type Backflow Preventors for Carbonated Beverage Dispensers, Post-Mix Type | ASSE 1032 |
115. Hose Connection Backflow Preventers (HCVB) | ASSE 1052, ASSE 1011, CSA B64.2 |
116. Laboratory Faucet Backflow Preventers (LFVB) | ASSE 1035, CSA B64.7 |
117. Pipe Applied Atmospheric Vacuum Breakers (AVB) | ASSE 1001, CSA B64.1.1 |
118. Pressure Vacuum Breaker Assemblies (PVBA/ PVB) | ASSE 1020, CSA B64.1.2 |
119. Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies (RPDA and RPDA-II) | ASSE 1047 |
120. Reduced Pressure Principal Backflow Preventers and Reduced Pressure Fire Protection Principal Backflow Preventers (RP and RPF) | ASSE 1013, CSA B64.4 |
121. Sanitary Yard Hydrants, Freeze Resistant | ASSE 1057 |
122. Spill Resistant Vacuum Breakers (SVB) | ASSE 1056 |
123. Vacuum Breaker Wall Hydrants, Freeze Resistant Automatic Draining Type | ASSE 1019 |
Drainage | |
124. Floor and Trench Drains | ASME A112.6.3 |
125. Roof, Deck and Balcony Drainsh | ASME A112.6.4 |
126. Siphonic Roof Drainsh | ASME A112.6.9, ASTM F2021 |
127. Trap Seal Protection for Floor Drains, Barrier Type | ASSE 1072 |
128. Vacuum Waste Collection Systems | CSA B45.13/IAPMO Z1700 |
Materials | |
129. Brazing Filler Metal | AWS A5.8M/A5.8 |
130. Drinking Water System Components | NSF 372 |
131. Drinking Water System Components - Health Effects | NSF 61 |
132. Food Equipment Materials | NSF 51 |
133. Plastics Piping System Components and Related Materials | NSF 14 |
134. Safing | ASTM C1306/C1306M, ASTM D4068 |
135. Sheet Copper | ASTM B152/B152M |
136. Surface Bonding Mortar, Standard Specification for Packaged, Dry, Combined Materials fori | ASTM C887 |
Methods | |
137. Capillary Joints by Soldering Copper and Copper Alloy Tube and Fittings, Standard Practice for Making | ASTM B828 |
138. CPVC/PVC, One-Step Method (solvent cement only) | ASTM F3328 |
139. Flaring Polyolefin Pipe and Tubing, Standard Practice for | ASTM D3140 |
140. Geomembranes and Related Materials, Index Puncture Resistance of | ASTM D4833 |
141. Geotextile, Determining Apparent Opening Size of a | ASTM D4751 |
142. Geotextiles, Grab Breaking Load and Elongation of | ASTM D4632 |
143. Geotextiles, Trapezoid Tearing Strength of | ASTM D4533 |
144. Grease Interceptors with FOG Sensing and Alarm Devices, Testing and Certification for | PDI-G 102 |
145. Heat Fusion Joining of Polyethylene Pipe and Fittings, Standard Practice for | ASTM F2620 |
146. Heat Fusion Joining of Polyolefin Pipe and Fittings | ASTM D2657 |
147. Hydro Mechanical Grease Interceptors with Appendix of Installation and Maintenance, Testing and Rating Procedure for | PDI-G 101 |
148. Installation of Thermoplastic Pipe and Corrugated Pipe in Septic Tank Leach Fields, Standard Practice for | ASTM F481 |
149. Maxim-Horizontal Directional Drilling for Placement of Polyethylene Pipe or Conduit Under Obstacles, Including River Crossings, Standard Guide for Use of | ASTM F1962 |
150. Measurement of Hydraulic Characteristics of Hydrodynamic Stormwater Separators and Underground Settling Devices, Standard Test Method for | ASTM C1745/C1745M |
151. PVC, Making Solvent Cemented Joints | ASTM D2855 |
152. Safe Handling of Solvent Cements, Primers and Cleaners Used for Joining Thermoplastic Pipe and Fittings, Standard Practice for | ASTM F402 |
153. Siphonic Roof Drainage, Plumbing Engineering &Design Standard | ASPE 45 |
Pools | |
154. Equipment and Chemicals for Swimming Pools, Hot Tubs, and Other Recreational Water Facilities | NSF/ANSI/CAN 50 |
155. Water Heater, Pools and Tubs, Electric | UL 1261 |
Wastewater Treatment | |
156. Aggregate, stone | ASTM C33/C33M |
157. Drainfield Trench Product Sizing for Gravity Dispersal Onsite Wastewater Treatment and Dispersal Systems | NSF 240 |
158. Evaluation of Components and Devices Used in Wastewater Treatment Systems | NSF 46 |
159. Filter Sand | ASTM C33/C33M |
160. FOG (Fats, Oils and Greases) Disposal Systems | ASME A112.14.6 |
161. Grease Interceptors | CSA B481 Series |
162. Grease Interceptors, Corrugated HDPE | ASTM F2649 |
163. Grease Interceptors, Hydromechanical | ASME A112.14.3 |
164. Grease Interceptors, Precast Concrete | ASTM C163 |
165. Grease Removal Devices | ASME A112.14.4 |
166. Leaching chambers | ASTM F2418, ASTM F2787, ASTM F2922, ASTM F3430 |
167. Non-Liquid Saturated Treatment Systems | NSF 41 |
168. Onsite Residential and Commercial Water Reuse Treatment Systems | NSF 350 |
169. Onsite Residential and Commercial Greywater Treatment Systems for Subsurface Discharge | NSF 350-1 |
170. Prefabricated Grease Interceptors | IAPMO Z1001 |
171. Prefabricated Septic Tanks and Sewage Holding Tanks, Design, Material and Manufacturing Requirements for | CSA B66.16 |
172. Residential Wastewater Treatment Systems | NSF 40 |
173. Residential Wastewater Treatment Systems - Nitrogen Reduction | NSF 245 |
174. Septic Tanks, Precast Concrete | ASTM C1227 |
175. Water Quality Units, Corrugated HDPE | ASTM F2737-11 |
Water Heating | |
176. Heat Exchanger, Single Wall Heat Transfer Fluidb | Category Code: HT-1 |
177. Water Heater, Commercial Storage Tank, Electric | UL 1453 |
178. Water Heater, Instantaneous, Electric | UL 499 |
179. Water Heater, Pools and Tubs, Electric | UL/ANSI 1261 |
180. Water Heater, Relief Valves | ANSI Z21.22/CSA 4.4 |
181. Water Heater, Relief Valve Drain Tubes | ASME A112.4.1 |
182. Water Heater, Residential Storage Tank, Electric | UL 174 |
183. Water Heater, Solid Fuel | UL 2523 |
184. Water Heater, Storage Tank, Oil Fueled | UL 732 |
185. Water Heater, Storage Tank 75,000 BTU/hr., Gas Fueled | ANSI Z21.10.1/CSA 4.1 |
186. Water Heater, Storage Tank and Instantaneous >75,000 BTU/hr., Gas Fueled | ANSI Z21.10.3/CSA 4.3 |
187. Water Temperature Limiting Devices | ASSE 1070 |
Water Treatment Devices & Chemicals | |
188. Drinking Water Distillation Systems | NSF 62 |
189. Drinking Water Treatment Chemicals - Health Effects | NSF 60 |
190. Drinking Water Treatment Units - Aesthetic Effects | NSF 42 |
191. Drinking Water Treatment Units - Health Effects | NSF 53 |
192. Residential Cation Exchange Water Softeners | NSF 44 |
193. Reverse Osmosis Drinking Water Treatment Systems | NSF 58 |
194. Ultraviolet Microbiological Water Treatment Systems | NSF 55 |
a. The specific standard edition adopted is specified in s. SPS 381.20.
b. NSF Registration Guidelines for Proprietary Substances and Nonfood Compounds. The NSF Nonfood Compounds Registration Program is a continuation of the USDA product approval and listing program, which is based on meeting regulatory requirements including FDA 21 CFR for appropriate use, ingredient, and labeling: https://info.nsf.org/usda/psnclistings.asp.
c. Nominal size = [LESS THAN EQUAL TO] 2-in. CTS.
d. May not be used in temperature/pressure relief valve drain lines unless they are tested and rated for excessive conditions of 210°F (98.9°C) and 150.0 psig (1034 kPa), per ASME A112.4.1 or ASTM F877.
e. Steel and malleable iron fittings used in a water supply system shall be galvanized in accordance with ASTM A123/A123M j =https://info.nsf.org/usda/psnclist- ings.asp.
f. Threaded joints shall only be used on pipe of sch. 80 or heavier.
g. Closed loop boiler feed only, standard does not require NSF/ANSI 372 or NSF/ANSI/CAN-61 conformance.
h. Design shall conform to ASPE 45-2018.
i. Portland, Type II