Wis. Admin. Code Department of Safety and Professional Services SPS 307.43

Current through August 26, 2024
Section SPS 307.43 - Instrumentation

All seismographs used to determine compliance with this subchapter shall meet the following minimum specifications:

(1) Seismic frequency range: 2 to 200 Hz, plus or minus 3 Hz.
(2) Acoustic frequency range: 2 to 200 dB, plus or minus 1 dB.
(3) Velocity range: 0.02 to 4.0 inches/second.
(4) Sound range: 110 to 140 dB linear.
(5) Transducers: Three mutually perpendicular axes.
(6) Recording: Provide time-history of waveform.
(7) Calibration: Be laboratory calibrated as often as necessary, but at least once every 12 months according to manufacturer's recommendations.

Wis. Admin. Code Department of Safety and Professional Services SPS 307.43

CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08.
Amended by, CR 17-034: am. (1), (2) Register March 2018 No. 747, eff. 4/1/2018